Troublesh ooting
P roblem
Decreased output. 1. Not enough air pressure and/
or air flow.
2. Obstructed trigger.
3. Incorrect lubrication or
not enough lubrication.
4. Blocked air inlet screen
(if equipped).
5. Air leaking from loose housing.
6. Mechanism contaminated.
Severe air leakage.
1. Cross-threaded housing
(Slight air leakage
components.
is normal,
especially on
2. Loose housing.
older tools.)
3. Damaged valve or housing.
4. Dirty, worn or damaged valve.
Housing heats
1. Incorrect lubrication or
during use.
not enough lubrication.
2. Worn parts.
Follow
all saf ety precautions w h enev er diag nosing or serv icing th e tool.
Disconnect air supply bef ore serv ice.
Item 61718
P ossible Causes
For tech nical q uestions, please call 1 -8 8 8 -8 6 6 -5 7 9 7 .
Lik ely Solutions
1. Check for loose connections and make sure that
air supply is providing enough air flow (CFM)
at required pressure (PSI) to the tool's air inlet.
Do not ex ceed m ax im um
2. Clean around trigger to ensure free movement.
3. Lubricate using air tool oil
according to directions.
4. Clean air inlet screen of buildup.
5. Make sure housing is properly assembled and tight.
6. Have qualified technician
clean and lubricate mechanism. Install in-line filter
in air supply as stated in Setup: Air Supply.
1. Check for incorrect alignment and uneven gaps.
If cross-threaded, disassemble and
replace damaged parts before use.
2. Tighten housing assembly.
If housing cannot tighten properly,
internal parts may be misaligned. Technician needs
to disassemble tool, align parts and reassemble.
3. Replace damaged components.
4. Clean or replace valve assembly.
1. Lubricate using air tool oil
according to directions.
2. Have qualified technician inspect internal
mechanism and replace parts as needed.
air pressure.