Temperature Setting
The temperature is factory set at 38°C,
however this may be overridden by simply
pressing the temperature override button
in when the handle reaches the stop and
continuing to turn the handle.
To reset the maximum temperature the
following should be carried out.
1. Remove the end cap.
2. Unscrew the handle screw.
3. Remove the handle.
4. Turn the valve spindle in the
required direction.
To increase the temperature
turn the spindle anti-clockwise
To decrease the temperature
turn the spindle clockwise.
5. Replace the handle, tighten
the screw and push fit the
cap back into position.