Maintenance
Non Return Valve
Maintenance
1. Isolate Water Supplies
Pull both shrouds away from the wall
surface to expose the filters. Isolate
both water supplies to the mixer by
unscrewing the filters fully, using a
10mm hexagonal key until they do
not turn any further.
2. Remove Mixer Valve
Unscrew both grub screws on both
connections and remove the mixer
tap from the connections.
3. Remove Internal Tube
Using long nose pliers pull the
internal tube from the inlets.
4. Replace Internal Tube
Replace the internal tube using a new
spare part supplied from Bristan.
Note: Internal tube with yellow flow
regulator must be fitted to the hot
inlet.
The internal tube with the Olive flow
regulator must be fitted to the cold
inlet.
Push the internal tube into the inlet
ensuring it is pushed in firmly.
5. Replace Mixer Tap
Push the mixer tap back onto the
connections and tighten the grub
screws.
Note: The grub screws must be
tightened equally.