Bristan H64WMT2 Instrukcje instalacji i instrukcja obsługi - Strona 14
Przeglądaj online lub pobierz pdf Instrukcje instalacji i instrukcja obsługi dla Produkt hydrauliczny Bristan H64WMT2. Bristan H64WMT2 20 stron. Single sequential d08 tmv3 thermostatic mixer taps
Maintenance
Cartridge Maintenance
We advise that the TMV is regularly
serviced in hard water areas to
maintain the flow of water.
Isolate both hot and cold water
supplies to the mixer tap
Pull both shrouds away from the wall
surface to expose the filters. Isolate
both water supplies to the mixer by
unscrewing the filters fully, using a
10mm hexagonal key until there is
resistance. Stop using the key at this
point and use fingers to "wiggle" the
filter out.
NOTE: Turning the hexagonal key
too far may result in seizing of the
filters.
1. Remove the control handle lever.
remove the cap and undo the screw
and remove the lever.
2. Unscrew the cartridge nut anti-
clockwise using a 30mm socket and
remove the cartridge from the TMV
body.
3. Place the cartridge in a suitable
solution until the cartridge is fully
de-scaled. Rinse thoroughly with
clean water to remove any debris.
4. Grease the seals with a
WRAS approved silicon grease
and carefully refit the cartridge.
5. Replace the lever handle, tighten
the grub screw and push-fit the cap
into position.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
14
Filter
Shroud
Cartridge
Piston &
Thermostat