Troubleshooting
Symptom
Sensor cable not connected.
Water supply not turned on.
Spout does
Solenoid valve not opening.
not operate
e.g no water
No mains electrical power to the
flow.
power supply box.
Blockage in water supply
pipework.
Inlet water supply pressure too
low.
No Mains power to the power
supply box.
No power to
the power
supply box.
Mains power supply failed and no
batteries fitted or batteries low.
Inlet filter is partially blocked.
Partially closed stop or service
Flow or water
valve in water supply pipework.
too low
Inlet water supply pressure too
low.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
12
Cause
Remedy
Check that the sensor cable is
connected. If not connected,
connect sensor cable. Refer
to the 'Electrical Connections'
section.
Turn on water supply and open
any isolation/service valves.
Contact Bristan Customer
Services.
Connect power supply
cable. Refer to the 'Electrical
Connections' section.
Remove pipework and flush to
remove any debris.
Remove inlet filter and clean
under running water.
Refer to 'Specification' section for
working pressures.
Connect power supply
cable. Refer to the 'Electrical
Connections' section.
Check mains power supply.
Insert/change batteries. Refer to
'Installation - Inserting batteries'
section.
Clean inlet filter. Refer to
'Maintenance' section.
Open stop or service valve.
Adjust inlet water pressure
accordingly. Refer to the
'Specification' section.