Specification
Specifications
Working Pressures
Min: 0.01 MPa
Max: 0.25 MPa
(0.1 bar)
3.0
2.0
4.0
1.0
1.0
5.0
0.
Pressure
BAR
Maximum Static Pressure:
1.0 MPa (10.0 bar)
Maximum Pressure Differential: 20:1
Temperature Differential:
The sensitive wax capsule will shut down the valve if the hot or
cold water supply fails, provided that there is at least a 10°C
difference between the mixed water temperature and the
remaining supply.
Dimensions (mm)
MT503CP
60
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Cold Water Supply
(2.5 bar)
3.0
2.0
4.0
5.0
0.
Min: 5°C Max: 20°C
Pressure
BAR
IMPORTANT
+/-2°C from set temperature
Inlet Water Temperature
Hot Water Supply
20°C
5°C
65°C Recommended
The inlet hot water must
be at least 10°C above the
required blend temperature.
To replace any spare parts
for your mixing valve, why not
scan the QR Code or
visit www.bristan.com
and search for your product.
145
80°C
65°C
TMV2 & TMV3 Designations
LP-B, HP-B, LP-W,
HP-W, LP-T, HP-T,
Spare Parts
105
Inlet & Outlet
Connection
15mm
Compression
LP-S, HP-S
3