KitchenAid 36" Instrukcje instalacji - Strona 2

Przeglądaj online lub pobierz pdf Instrukcje instalacji dla Płyta grzewcza KitchenAid 36". KitchenAid 36" 5 stron. 30” and 36” gas sealed burner glass cooktops
Również dla KitchenAid 36": Instrukcja instalacji (16 strony)

KitchenAid 36
30" cooktop
30" min. base cabinet
is required. If cabinet has
a drawer, a 3-l/2" depth clearance from the
countertop to the top of the drawer (or other
obstruction)
in base cabinet is required.
36" Cooktop
36" min. base cabinet
is required.
If cabinet
has a drawer, a 3-l/2" depth clearance from the
countertop to the top of the drawer (or other
obstruction)
in base cabinet is required.
Fire Hazard
Do Not obstruct
the flow of combustion
and ventilation
air.
Personal
Injury Hazard
Avoid installing
cabinet
storage
above the
cooking
surface.
If cabinets
are already
installed,
reduce the hazard of reaching
over a heated cooking
surface
by
installing
a range hood. The range hood
should extend a minimum
of 5 inches out
from the bottom front of the cabinets.
Reaching
over a heated cooking
surface
could result in a serious
burn or other
personal
injury.
Electrical
Shock Hazard
It is the customer's
responsibility:
l
To contact
a qualified
electrical
installer.
l
To assure that electrical
installation
is
adequate
and in conformance
with
National
Electrical
Code ANSI/NFPA
70 -
latest edition and all local codes
and ordinances.
Failure to do so could result in fire: .
electrical
shock or other personal
mjury.
Take special
care when drilling
holes into
the wall for electrical
wiring.
Electrical
wires may be concealed
behind the wall
covering.
Failure to do so could result in fire,
electrical
shock or other personal
injury.
For 30"
cooktop
- 30" min. cabinet
width
above
cooklop
For 36"
cook-lop - 36" min. cabinet width
yabove
cwMop
t
13"
max.
wper
cabinet
+
depth
See Note'* for
minimum
clearances
centered
with
l
Note: 30" min. when bottom of -
cord
between
the
cooktop
and
wood or metal cabinet
is
cabinets.
protected
by not less
than
114"
flame retardant millboard
covered
with not less than No.
28 MSG sheet steel, 0.015"
Note: Clearances
specified are for combustible
stainless
steel, 0.024"
4
walls and materials that have a density of 20 or
aluminum
or 0.020" copper.
more pounds per cubic foot. No evaluation of
::;%h:~:;~
;%%
the
clearances
has been made for installations
adjacent to materials that are less than 20
and the bottom o an
unprotected
wood or metal
sheet.
pohnds per cu. ft. or to plastic tiles and sheeting.
For new installations:
30" cooktop:
36" Cooktop:
B 1 ;T;in.
opening
c
2-5/8"
min. cabinet
space to backsplash
or vertical
wall
2-318" min. space to
D
front edge of
countertop
5-114"
min. cabinet
E
space both sides of
cooktop
from a
combustible
surface
A
18-314"
min.
opening
depth
B
33-l/4"
min.
opening
width
C
2-5/8" min. cabinet
space to backsplash
or vertical
wall
4-5/8"
min. cabinet
E
space both sides of
cooktop
from a
combustible
surface
For reolacement installations:
30" cooktop:
36" Cooktop:
1 k3l4"
min., 20-518" max.
opening
depth
18-314" min., 20-518"
opening
depth
26-112" min., 29518" max.
opening
width
33" min., 34-718" max.
opening width
Mobile home installation
The installation of this cooktop must conform to the
Manufactured
Home Construction
and Safety
Standards, Title 24 CFR, Pat-l 3280 (formerly the
Federal Standard for Mobile Home Construction
and
Safety, Title 24, HUD Part 280); or when such
standard is not applicable, the Standard for
Manufactured
Home Installations
1982
(Manufactured
Home Sites, Communities
and
Setups), ANSI A225, l/NFPA 501 A -
1987, or latest
edition, or with local codes.
Copies of the standards listed may be obtained from:
* National
Fire Protection
Association
Batterymarch
Park
Quincy,
Massachusetts
02269
* American
Gas Association
1515 Wilson Boulevard
Arlington,
Virginia
22209
Before you start...
WARNING: If the information in this
manual is not followed exactly, a
fire or explosion may result
causing property damage, personal
injury or death.
- Do Not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
- WHAT TO DO IF YOU SMELL
GAS
l
Do Not try to light any
appliance.
l
Do Not touch any electrical
switch; do not use any phone
in your building.
l
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas
supplier's instructions.
l
If you cannot reach your gas
supplier, call the fire
department.
- Installation and service must
be performed by a qualified
installer, service agency or the
gas supplier.
Proper installation
is your responsibility.
Make sure
you have everything
necessary for correct
installation.
It is the responsibility
of the installer to
comply with the installation clearances
specified on
the seriavrating
plate. The serial/rating
plate can be
found on the bottom of the cooktop burner box.
Check location
where cooktop will be installed. The
location should be away from strong draft areas,
such as windows. The cooktop should be located for
convenient
use in the kitchen.
ALL OPENINGS
IN THE WALL OR FLOOR WHERE
THE COOKTOP
IS TO BE INSTALLED
MUST BE
SEALED.
Grounded
electrical
outlet is required. See
"Electrical requirements."
Proper gas supply
connection
must be available.
See "Gas supply requirements."
Countertop
opening
dimensions
that are shown
must be used. Given dimensions provide required 0"
clearance.
Cabinet
construction:
This appliance is designed
for use in a base cabinet with a depth of 24"
The
maximum depth for overhead cabinets is 13". The
minimum vertical clearance between the cooking
surface and the overhead cabinets is 30". Overhead
cabinets installed at either side of the appliance
must
be a minimum of 18" above the cooking surface. The
minimum distance between the front edge of the
countertop and the front edge of the cooktop is 3/4".
The minimum horizontal distance between the
overhead cabinets above the appliance are shown
for your model number.
New installations
follow minimum dimensions given.
Replacement
installations
-
Be sure that front
edge of cooMop is at least 1 -l/2" back from front
edge of countertop.
When installing
cooktop
over a built-under
oven.
Do Not fasten cooktop to countertop with clamps.
Cooktop then will be easy to remove if servicing is
ever necessary.
Note: The sealed gas cooktop is manufactured
for
use with NATURAL gas. Conversion to L.P. gas can
be made with Kit No. 4175385, available from your
KitchenAid dealer or authorized parts distributor.
Important:
Observe
all governing
codes and
ordinances.
Failure to meet codes and
ordinances
could
lead to fire or electrical
shock.
Panel A