PRODUCT MODEL NUMBERS
KFGS306V
KFGS366V
Gas Supply: This cooktop is factory set for use with
natural gas. Cooktop can be converted to LP gas.
Conversion must be done by a qualified service
technician. Provide a gas supply line of 3/4" (1.9 cm)
rigid pipe to the cooktop location. A smaller size pipe on
longer runs may result in insufficient gas supply. Pipe-
joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®
tape. With LP gas, piping or
tubing size can be 1/2" minimum. Usually, LP gas
suppliers determine the size and materials used in the
system.
No attempt shall be made to convert the cooktop from
the gas specified on the model/serial rating plate for use
with a different gas without consulting the serving gas
supplier. See the Gas Conversion instructions provided in
the package containing literature.
Electrical: A 120 volt, 60 Hz., AC only, 15-amp fused
electrical circuit is required. A time-delay fuse or circuit
breaker is also recommended. It is recommended that a
separate circuit serving only this cooktop be provided.
PRODUCT DIMENSIONS
A
A. 30
" (76.7 cm) on 30" (76.2 cm) models,
36 " (92.0 cm) on 36" (91.4 cm) models
B. 21" (53.3 cm)
C. 3" (7.6 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
®
Gas Built-in Cooktop
KFGU706V
KFGU766V
B
C
INSTALLATION CLEARANCES
C
J
M
A. 30" (76.2 cm) on 30" (76.2 cm) models; 36" (91.4 cm) on 36" (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of
uncovered wood or metal cabinet (24" [61.0 cm] minimum clearance if bottom of
wood or metal cabinet is covered by not less than 1/4" [0.6 cm] flame retardant
millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm]
stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper). If installing
a range hood see NOTES.*
D. 13" (33.0 cm) recommended upper cabinet depth
E. 1-1/8" (2.8 cm)
F. 20" (50.8 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum
horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61.0 cm) of right rear corner of cutout
I. 29" (73.7 cm) on 30" (76.2 cm) models; 35-1/4" (89.5 cm) on 36" (91.4 cm) models
J. 24" (61.0 cm) minimum countertop depth is required
K. 2-7/8" (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below underside of countertop.
Cabinet floor: anywhere within 6" (15.2 cm) of rear wall is recommended
M. 8" (20.3 cm) minimum distance to nearest left side combustible surface.**
N. 8" (20.3 cm) minimum distance to nearest right side combustible surface.**
30" (76.2 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) minimum + 29"
(73.7 cm) cutout for cooktop or 77" (195.6 cm)
36" (91.4 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) minimum + 35-1/4"
(89.5 cm) cutout for cooktop or 83-1/4" (211.5 cm)
**M + N combined must be at least 48" (122.0 cm) minimum overall
Example 1: M = 8" (20.3 cm) left side + N = 40" (101.6 cm) right side = 48" (122.0 cm)
Example 2: M = 24" (61.0 cm) left side + N = 24" (61.0 cm) right side = 48" (122.0 cm)
NOTES:
After making the countertop cutout, some installations may require notching down the
base cabinet side walls to clear the cooktop base. To avoid this modification, use a
base cabinet with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the countertop to the top
of the drawer (or other obstruction) in base cabinet is required. The drawer depth may
need to be shortened to avoid interfering with the regulator.
*If installing a hood above the range, follow the hood instructions for dimensional
clearances above the cooktop surface.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
A
D
B
F
K
E
H
L
I
G
N
Ref. 8286867B
06-25-08