Gammaflux TTC Zaawansowana konfiguracja/rozwiązywanie problemów - Strona 2

Przeglądaj online lub pobierz pdf Zaawansowana konfiguracja/rozwiązywanie problemów dla Kontroler temperatury Gammaflux TTC. Gammaflux TTC 4 stron.

Gammaflux TTC Zaawansowana konfiguracja/rozwiązywanie problemów
0
Row selected
10
Row in alarm
20
30
* Power "On"
* Automatic
(Lit when
temperature
all unlocked
set point
zones are "On")
change/ view
+100 +10 +1
2 3 2
-100 -10
-1
* Power "Off"
Trim – Permanent,
(Lit when
automatic set point
all zones
change for zone(s)
are "Off")
selected, (±20ºF /11ºC
default). Select zone(s),
enter change amount,
all selected zone(s)
will change
Zone selected
when lit
0
1
2
Manual or %
operation when lit
* Saved in menu
Actual value
2 3 2
Degree C if lit,
Degree F if dark
* Manual %
output
set point,
change/ view
Select
Enter
* Automatic/
manual/
locked
operation,
change/
view
Alarm for zone when lit.
Select zone,
check alarm area
3
High temperature alarm
(+20ºF / 11ºC default)
selectable in advanced
setup
Temperature holding
set point (automatic) or
zone "On" (manual)
Low temperature alarm
(-20ºF / 11ºC default)
selectable in advanced
setup
Temperature
Select
C
Deviation from
automatic set point
Boost – Temporary increase to
zone(s) selected. Temperature
and time limit adjustable in
advanced setup (To cancel boost,
press boost)
Standby – (selected zones)
Change automatic set point to
temperature in advanced setup
(220ºF/104ºC default); cut manual
% set point in half. May indicate
material protection/standby remote
input, see advanced set up.
(To cancel standby, press standby)
% Output
Amps
Group Selection Area
"All Group" –
Selects all
zones in the
system
High temperature
(+20ºF / 11ºC default)
Low temperature
(-20ºF / 11ºC default)
Thermocouple (T/C) Open –
The T/C connection is broken
Thermocouple Reversed –
The T/C connection is wired
+ to - at some point
Thermocouple Pinched – The T/C is
pinched or the controller thinks it is
pinched. (Default: 100% output,
must see +20ºF/11ºC in 5 minutes).
True Pinch –Temperature reading too
far away to control – runaway.
False Pinch – Heater is too small to
heat the zone
Open Fuse – Fuse on module bad
Shorted Heater – The heater is
shorted or exceeds the maximum
rating of the module
Open Heater – The heater
connection is broken
Uncontrolled Output – The module
has an unregulated output. All zones
on module shut "off" automatically
Clear Alarm, turn off light /relay
1
* "Custom Group" –
Stores user zone
group. Select
zones to save,
press custom
group button
until flashes
(5 seconds)