Input resistance: 10MΩ in average.
Maximum input voltage: 600V RMS
• Show true virtual value. Frequency response: 45~400Hz
• Accuracy guarantee range: 5-100% range, short circuit allows <10
residue readings.
• Non-sinusoidal wave counts add error by crest factor:
When crest factor is 1~2: Add 3%.
When crest factor is 2~2.5: Add 5%.
When crest factor is 2.5-3: Add 7%.
3. Resistance measurement
Range
200.00Ω*
2.000kΩ
20.00kΩ
200.0kΩ
2.000MΩ
20.00MΩ
Range: measured value=measurement display value-meter pen
short circuit value - Open-circuit voltage is about 1V
4.
circuit on-off,
Range
Resolution
0.1Ω
1mV
Overload protection: 600V-RMS
5. Capacitance measurement
Range
2nF
20.00nF~200.0μF
2.000mF~20.00mF 1μF~10μF
Overload protection: 600V-RMS. ≤1μF measured capacitance, it is
suggested to use ZERO measurement mode to ensure accuracy.
Resolution
0.1Ω
10Ω
100Ω
1kΩ
10kΩ
Overload protection: 600V-RMS
diode measurement
Resistance value for circuit disconnect:>
150Ω, buzzer makes no sound; Resistance
value for circuit conduct: <1Ω on, buzzer
beeps continuously.
Open circuit voltage is 3.2V: normal voltage
for silicon PN junction is 0.5~0.8V.
Resolution
1pF
10pF~100nF
Accuracy
± (1.0%+2)
± (1.2%+3)
Accuracy
Accuracy
± (4%+10)
± (4%+5)
±10%
13