10. SPECIFICATIONS

10.1. General Specifications

Function
Display
Measurement
Memory
Sampling
Operating Temperature
Operating Humidity
Power Supply
Power Current
Weight
Dimension
Accessories included

10.2. Electrical Specifications

Function
Air Velocity
Measurement
m/s
km/h
ft/min
MPH
knots
Notes: m/s-meters per second km/h-kilometers per hour, ft/min-feet per
minute MPH-miles per hour, knots-nautical miles per hour

10.3. Temperature Specifications

Function
Measuring Range
Resolution
Accuracy
Range
46.7mmx60 mm larger LCD display
Dual function meter's display
m/s (meters per second)
km/h (kilometers per hour)
ft/min (feet per minute)
MPH (miles per hour)
knots (nautical miles per hour)
Temp. ---°C ' °F
Data hold
Maximum and Minimum with recall
Approx.0.8 sec
0°C to 50°C (32°F to 122°F )
Less than 80% RH
9V battery
Approx. DC 60~90mA
280g
210mmx75mmx50mm
Hot wire sensor & 9V battery
Range
Range
Resolution
0.1 ~25.0m/s
0.01m/s
0.3~90.0km/h
0.1 km/h
20~4925/min
1ft/min
0.2~55.8 MPH
0.1 MPH
0.2~48.Sknots
0.1 knots
Range
0°C to 50°C (32°F to 122°F )
0.1 °/0.1°F
± 1°C/1.8°F
Accuracy
±(5%+ 1 d)
reading
11