4.2. MINIMUM VOLTAGE SPECIFICATIONS
Battery Type
Button Cell 1.5V
AAA-N-1.5V
AA-C-D-1.5V
Lithium 3V
6V
9V
12V
15V
22.5V
5. OPERATION
5.1. TESTING A BATTERY
NOTICE: Always identify the battery polarity before testing.
NOTICE: To avoid excessive drain on the battery under test, do not press
the push button (5) down when using the test leads or short the test leads
across one another when pressing the button (5).
NOTICE: Do not allow the test leads to touch the metal positive and
negative contact points on the tester during any battery test.
1. Set the battery selector (4) to the type of battery you are testing. If the
battery selector (4) is incorrectly positioned, an inaccurate test will result
and may damage the tester and cause excessive drain on the battery.
2. Touch the red test lead (6) to the positive (+) terminal on the battery and
the black test lead (7) to the negative (-) terminal on the battery.
3. Observe the battery condition on the LCD display (1).
4. When testing 9V rectangular batteries, position the positive (+) and
negative (-) battery terminals directly onto the positive and negative
contact points (3 and 2), then observe the battery condition on the LCD
display (1).
Load Current
50mA
50mA
150mA
100mA
10mA
10mA
10mA
10mA
10mA
Min Voltage for Good Indication
1.125V ± 0.09V
1.125V ± 0.09V
1.125V ± 0.09V
2.25V ± 0.18V
4.5V ± 0.36V
6.75V ± 0.54V
9V ± 0.72V
11.25V ± 0.9V
16.875V ± 1.35V