InstallationInstructions
Before Installation
1.
Establish a suitable location for the meter where it will have sufficient GSM signal quality. You should use a
GSM signal analyser as near as possible to where the meter will be installed to check for signal quality on at
least 1 network.
The meter has a network roaming SIM card that will lock onto the strongest available UK network operator
Mounting the meter
2.
The meter must be securely mounted to a wall or meter board.
a.
Unscrew and remove the lower-front meter panel to expose the terminal connections.
b.
Mount the meter using a suitable round headed screw on a wall or meter board.
c .
The screw depth should be adjusted so that the head fits snugly under the hanging point and the
meter is held firm against the wall or board
d.
Finally the meter should be firmly screwed to the wall or board using the two mounting holes located
under the terminal cover
3.
The meter should be installed indoors or in an IP rated cabinet. The meter should not be in an enclosed metal
container unless an external antenna is being fitted.
ForEmliteEMA1SinglePhaseGPRSMeter
It is recommended that this electric meter is installed by a competent
electrician in accordance with BS7671 and the IET Code of Practice
+44(0)1883 460411
www.decmetrics.co.uk