8. Functional Design

1 - Press the up and down key to adjust the Emissivity.
2 - Press the up key to turn the laser on or off and the down key to turn the
backlight on or off.
3 - Press the MODE button to change MAX/MIN/DIF/AVG.
4 - ln the measuring time, if the Type-K thermocouple is connected, the
Type-K data will displays in the lower left quarter automatically. In this
time, cannot change MAX/MIN/DIF/AVG.
5 - To set values for the High Alarm (HAL), Low Alarm (LAL) and Emissivity
(EMS), press and hold the MODE button until the appropriate code
appears in the display, press the UP and DOWN buttons to adjust the
desired values.

9. MODE Button Function

Ÿ Pressing the mode button also allows you to access the set state, Emissivity
(EMS), °C/°F, HAL on/off, HAL adjustment, LAL on/off, and LAL adjustment.
Each time you press the set key you advance through the mode cycle.
• The diagram shows the sequence of functions in the mode cycle.
• EMS adjustment. The Emissivity(EMS) digitally Adjustable from 0.10 to
1.0.
°C/F.
Press the up/down button to change the temperature unit (°C or °F)
HAL/LAL on/off. Press the up button or down button to turn on or off.
Press the Measurement Trigger to confirm the High/Low alarm mode.
HAL/LAL adjustment, the High/Low alarm adjustable form -50 to 1000°C
(-58 to 1832°F).
MAX MIN DIF AVG indicates the MAX MIN DIF AVG which is recorded by
pressing and releasing the "ON/OFF" button each time.
MAX MIN DIF AVG display
MAX = maximum .Maximum value of measurement.
MIN = minimum. Minimum value of measurement.
DIF = difference. Difference value of measurement.
AVG = average. Average value of measurement.
9