Green Digital Power-tech G100-12A Podręcznik użytkownika - Strona 2

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Ładowarka Green Digital Power-tech G100-12A. Green Digital Power-tech G100-12A 2 stron. G100-xxa series 12-48v lead-acid battery charger

Brief Introduction
G100-XXA is a main member of digital-chargers from Green Digital
Power-tech Co., Ltd. It represents today's new technology for lead-acid type
battery charging. G100-XXA programmed four auto stages ( Ud-Im-Uo-Up)
charging process,It is designed for all kinds of 12V~36V lead-acid battery,
such as SLA, AGM and Gel battery. Stage "Ud" desulfurating the battery
through 18V pulse (for 12V battery),When the battery recovered, stage "Im"
will give bulk current charging. Then, "Uo" stage is followed, the output voltage
is limited on 14.7V( for 12V battery); When the battery is nearly full, stage"Up"
will turn on duty. At this stage, the battery is charged completely and the
charger give some pulse to maintenance the battery.
Further, G100 can display the charging process, indicate the battery
capacity from 25% to 100% timely. This is helpful for user.
For more safety, G100 will inter protection mode when the battery polarity
reversed or the output connectors shorted.
Specification for G100-XXA
Input Voltage
100-240VAC,50-60Hz
Input Current
1.6A
Back current drain
1.3mA
Charge voltage
G100-12A
14.7V+-1%
Limited
Bulk charge current
5.5A+-8%
Operate Temperature
-20℃~50℃,
Natural convection. Do not cover the charger.
Cooling
Charge principle
4 stages: Ud-I-Uo-Up (Note: For 24V and 36V type, Ud is absent)
All types of 12V lead-acid batteries.( SLA, Gel, AGM....)
Battery type
Battery capacity
7-80Ah
Size
170X71X51mm
Dust protected, Water splashing resistance)
Enclosure
IP54 (
Weight
400g
G100-24A
G100-36A
G100-48A
29.4V+-1%
44.1V+-1%
58.5V+-1%
2.8A+-8%
1.8A+-8%
1.7A+-8%
Display Panel
Power on
(When
AC
input OK)
When this LED lamp is
"on" and other 3 lamps
are "off", this means the
charger
enter
the
recover(
desulfurating)
process.
How to use:
Connect the AC cord to the socket, The "power" lamp will light on solid.
1.
Connect positive charger clip (red) to positive battery terminal, the black clip
2.
to negative. (You can use other dc plugs to connect battery), the
"25%~100%" lamps will light on flowing. If the battery polarity reversed or
output shorted, all lamps will flashing, please check the setup.
Depend on the charged capacity, 25%~100% lamps will lights up solid
3.
sequence, until the battery is fully charged. Then you can power off the
charger and disconnect the battery or you can charge a new battery if you
need.
The table shows the duration of 80% state charged for an empty battery.
Battery type(Ah)
G100-12A
12
Not recommend
22
5 hours
40
9 hours
80
16 hours
Charging process indicator:
Indicate battery capacity from 25% to
100% when charging.
All lamps flashing means battery
polarity reversed or output shorted.
All lamps are "off" means no battery.
G100-24A
G100-36A
5 hours
7 hours
9 hours
12 hours
14 hours
20 hours
Not recommend
Not recommend