CHAPTER 1
SAFETY
m
DANGER
m
WARNING
m
CAUTION
m
DANGER
m
CAUTION
© Airflow - we reserve the right to make changes without prior notice
1.0
Important information
In order to ensure complete and effective operation and for your own safety, all of the following instructions should
be read carefully and observed.
This document should be regarded as part of the product and as such should be kept accessible and durable to
ensure the safe operation of the fan. All product-related safety regulations must be observed.
1.1 Warning instructions
The accompanying symbols are safety-relevant prominent warning
symbols. All safety regulations and/or symbols in this document must
be absolutely adhered to, so that any risks of injury and dangerous
situations are avoided!
1.2 Safety instructions
Special regulations apply for use, connection and operation; consultation
is required in case of doubt. Further information can be found in the relevant
standards and legal texts.
With regard to all work on the fan, the generally applicable safety at work and
accident prevention regulations must be observed!
•
The following must be observed before all cleaning, installation,
servicing and maintenance work or before opening the terminal
compartment:
– Isolate the device from the mains power supply and secure against
being switched on again!
– The rotating parts must first come to a standstill!
– Once the rotating parts come to a standstill, a waiting time of 3 min.
must be observed, as dangerous voltages may be present due to internal
capacitors even after disconnection from the mains!
• All product-related safety regulations must be observed!
If applicable, further country-specific regulations must also be observed!
• Protection against contact must be ensured pursuant to DIN EN 13857 in
the installed condition (see section 2.9)!
Contact with rotating parts must be avoided.
• A uniform air inlet and free outlet must be ensured!
• When using a vented fire place (chimney) in a ventilated room, there must
be sufficient supply air for all operating conditions (consult
chimney sweep).
The current locally applicable regulations and laws must be observed!
1.3
Application
– Normal use:
The wall installation units Unohab are intended for external building wall installation. The air outlet is on the external
side of the wall via a stainless steel panel. A lockable plastic panel serves this purpose on the internal side of the
wall with an integrated non-woven air filter class Coarse and sound insulation.
In order to ensure balanced ventilation, at least 2 units, which operate in modes with regard to operating mode
(supply air/extract air), are required for one residential unit. Depending on the overall ventilation requirement of the
residential unit, more than 2 units are normally installed and the individual volume flows are automatically adjusted
by means of the central control unit.
When operating under difficult conditions, such as high levels of humidity, long standstill periods, excessive loads
and climatic, technical or electronic influences, consult with Airflow technical services, as the standard version
is not suitable for this.
Any use other than the intended use is prohibited!
Unohab Unit
4
Installation and Operating Instructions