Green Hat Sun Combi 600 Instrukcja obsługi Świadectwo gwarancji - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja obsługi Świadectwo gwarancji dla Grzałka Green Hat Sun Combi 600. Green Hat Sun Combi 600 7 stron. Metal hybrid heater
ENGLISH
Safety information
Do not cover the heater with any objects. Do not dry things.
DANGER: Do not cover the heater in order to prevent overheating.
ATTENTION! For your own safety, before using the heater carefully read the instruc-
tion and always keep it in an accessible location.
Use the heater only with the current which is stated in the technical data. During operation, the heater is warmed, to prevent burns, do not
touch the hot surface.
Do not immerse the heater into the liquid, it can lead to electrical shock. Do not reach for the device in case of falling into the liquid, immediately
pull the plug out of the socket.
Do not use the heater near the bath, shower, swimming pool and other containers with liquid.
Do not use a heater with a damaged cord, plug or with the presence of other injuries. In case of malfunction contact a qualified service center.
Use the heater only for its intended purpose according to the present instruction for. Any other use is prohibited and may result in fire, electric
shock or injury.
Heater installation
Do not place the heater directly under the outlets.
ATTENTION! Do not place the heater on the ceiling!
Do not connect the heater to the power supply until installation is complete.
The heater must be installed on the vertical surface at the height of not less than 0.2 meters above floor level. On top of the heater is necessary
to provide the free space of 0.2 m for the free exit of warm air.
It is not allowed to place furniture, household radio, TV - and computer equipment closer than 500 mm from the heater, in order to prevent
obstacles for the free air circulation.
Electric power socket and connector must be mounted at the height ensuring the inaccessibility of children.
Drill holes in the wall with the diameter of 8 mm according to the installation scheme for the particular model. Insert to the holes special plastic
plugs that are supplied with the set. Having mounted the plugs, tighten with screws metal fastenings and screw L-shaped screws.
Install the heater, which grooves should coincide with the fastening.
Connection scheme
Remember! If the devise isn't used for a long time, it's necessary to turn it off and
pull the plug.
The heater can be connected by the supply wire and plug into the electrical outlet.
During the usage of heaters for indirect heating of the building manufacturer recommends the use of connection by remote thermostat,
which provides automatic support of the necessary temperature and significant saving in electricity consumption. The thermostat should
be selected according to the number of certain models of the heaters and certain specific technical data, so for the correct choice of the
thermostat, refer to the specialist company.
Models, not equipped with thermostat, are designed for connection through the "Smart Home" system or remote thermostat with functions:
WI-FI control, adaptive switching on, daily and weekly programming, open window control.
8
Heater exploitation
The device can be used by children of 8 years and older and by persons with reduced physical, sensory or mental abilities or lack of experience or
knowledge if they are under control of person responsible for their safety or have been instructed concerning the safe use of the device and un-
derstand the possible danger. Children should not play with the device. The device shouldn`t not be cleaned or serviced by children unattended.
Children under 3 years should not be allowed to the heater, unless they are supervised by an adult. Children from 3 to 8 years have the oppor-
tunity to turn on / off the heater if it has been properly installed and children are under supervision or have been instructed on the safe use of
the heater and understand the possible dangers. Such children should not use the plug, heater control devices and clean the heater, or carry
out maintenance.
DANGER: Do not use in case of damage of the front surface!
DANGER: Models, which aren`t supplied with the automatic room temperature control
device are forbidden for the usage in small rooms, if they`re emplyed with people who
are unable to leave the premises, and if the constant care of them is not possible.
ATTENTION! Some parts of the heater may be hot and cause burns. Particular
attention should be given during the presence of children and vulnerable people.
Cleaning and Maintenance
The heater does not require special care. It should be cleaned regularly, dust the surface, since the dust has a negative impact on the perfor-
mance of the device. Wet cleaning is allowed when the heater is turned off.
ATTENTION! Turn off the heater before cleaning. Cleaning the heater using steam or
pneumatic purifiers for safety reasons is not permitted.
Turn off the device and let it cool before each cleaning. Use for cleaning household cleaners without abrasive materials for glass ceramic or
stainless steel.
Clean the device using the wet cloth with a small amount of detergent.
Finally, dry the device with a clean cloth.
In the case of the lifetime end the heater requires utilization in accordance with norms, rules and means in the territory of the location. Do not
throw away the heater together with the rest household garbage.
Warranty obligations
The manufacturer guarantees heaters compliance with the requirements during the observance of the terms of transportation, storage, instal-
lation and operation.
Carefully check the appearance of the device and its packaging. In the case of mechanical damages of the heater, which could occur due to the
fall / strokes or absence of a serial number of the heater manufacturer has the right to refuse in warranty service to the Buyer.
Manufacturer provides warranty: 5 years for heating element on 2 years for built-in digital thermostat. During the absence of the stamp and
the date of purchase the warranty period of the heater is calculated from the date of manufacture.
The service life is 30 years. Shelf life is unlimited if stored in a dry ventilated room with a relative humidity of 60% and no more than 20 stacking
units in height.
During violation the rules of storage, installation, exploitation and this instruction customer claims are not accepted.
Warranty service of the purchased heater is carried out through the Seller, or authorized service facilities if available in the particular area..
Utilization
9