IKEA GRILJERA Podręcznik użytkownika - Strona 28

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Okap wentylacyjny IKEA GRILJERA. IKEA GRILJERA 36 stron.
Również dla IKEA GRILJERA: Podręcznik użytkownika (16 strony), Podręcznik (16 strony)

IKEA GRILJERA Podręcznik użytkownika
ENGLISH
28
For the indispensable introduction of fresh air
in the room, a similar opening of at least 100
cm
directly to the outside must be provided
2
at a height near floor level so as not to be
obstructed on the inside or outside of the wall
and not to hinder the correct combustion of
the burners and the regular extraction of
vitiated air, and with a height difference of at
least 180 cm with respect to the outlet
opening.
The quantity of air necessary for combustion
must not be less than 2 m
/h for every kW of
3
power (see total power in kW on the
appliance rating plate).
In all other cases, when there are other
appliances in the same room, or when direct
natural ventilation is not possible and indirect
natural ventilation of forced ventilation has to
be created, contact a qualified specialist for
carrying out installation and preparing the
possible ventilation system in strict compliance
with current regulations.
Flues already used by other appliances must
not be used for exhausting combustion
products.
i
IMPORTANT: the covering of the cabinets
must be in heat resistant (min. 90°C) material.