Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
iMPORTANT: The hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70,
latest edition, or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
m A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit is
required. A time-delay fuse or circuit breaker is also
recommended.
It is recommended
that a separate circuit
serving only this hood be provided.
m Do not ground to a gas pipe.
m Check with a qualified electrician if you are not sure range
hood is properly grounded.
m Do not have a fuse in the neutral or ground circuit.
m The range hood must be connected with copper wire only.
m The range hood should be connected directly to the fused
disconnect (or circuit breaker) box through flexible armored
cable or flexible metallic conduit.
m Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70, latest edition, or CSA
Standards C22.1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91, latest edition, and all local codes and
ordinances.
INSTALLATION INSTRUCTIONS
Because of the size and weight of this island hood, the chimney
support must be securely attached to the ceiling.
m For plaster or drywall ceilings, the chimney support must be
attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support
structure must be able to support 80 Ibs (36.3 kg).
m Do not cut a joist or stud unless absolutely necessary. If a
joist or stud must be cut, then a supporting frame must be
constructed.
m Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
m We recommend the hood be installed 30"-36" (76.2 cm -
91.4 cm) above the countertop.
m Check your ceiling height and the hood height maximum
before you select your hood.
K = ceiling height
C = countertop
height
P = preferred hood height -
30"-36"
(76.2 cm - 91.4 cm)
is recommended
H = K-C-P
ceiling to bottom of hood
S = H-13/4 '' (4.4 cm)
chimney assembly height
1. Select a hood preference height (P) that is comfortable for the
user. 30"-36"
(76.2 cm - 91.4 cm) is recommended.
2. Calculate the hood height for your installation (H = K-C-P).
3. Confirm that the dimension (H) is within the minimum to
maximum dimensions. See "Product Dimensions" in the
"Location Requirements" section.
4. Calculate the chimney structure height (S = H-13/4'' [4.4 cm]).