Installation

Installation
z
Caution!
The device is intended for indoor use. Do not expose it to either extreme tem-
peratures or extreme humidity at any time and choose its setup site accord-
ingly. The ambient temperature must fall within the range from 5 to 40 °C at all
times, the relative humidity of the air must not exceed 90 %.
Do not set up the device in the immediate vicinity of radiators or other heat sources.
Avoid sites which are exposed to direct sunlight.
Create sufficient space for lines and cables.
Ensure sufficient ventilation of the device.
For cable connections, use only cables which have been part of the delivery or are
otherwise suitable and which help to suppress electric interference.
When laying out the lines and cables, make sure that they cannot be easily damaged
and ease wherever possible tensile loads and stresses.

Connections

Dome cameras
Connect the dome cameras (maximum 31 cameras per converter) to the converter's
DOME contacts.
Use Belden cables for connections if possible or twisted pair cables, based on the same
Belden standard.
Pin assignment DOME connector
1 Ground
2 Signal –
3 Signal +
Matrix switcher and further receivers or converters
You can lock the protocol converter in place on its own or as one of several devices into
a RS422 bus on the CEC C328 matrix switcher. The order or position of each of the sin-
gle devices has no particular effect because each device has its own address within the
bus system.
8