Berner ARISTOCRAT Series Instrukcja instalacji i konserwacji - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja instalacji i konserwacji dla Grzałka Berner ARISTOCRAT Series. Berner ARISTOCRAT Series 8 stron. Air door
I. UNCRATING
Carefully examine the carton(s) for damage before opening. If the carton
is damaged, immediately notify shipping company. If the unit(s) were
shipped on wooden skids, remove protective wood and banding straps
securing the carton(s) to the skid. Open the carton(s) and remove all pro-
tective packaging. Remove the plastic cover housing by lifting vertically.
Remove and discard four (4) nuts and washers holding the motor/blower
section to the bottom of the carton. Remove motor/blower section from
the carton.
CAUTION: ONLY LIFT THE UNIT BY GRASPING INLET RINGS ON THE
BLOWER HOUSING WITHOUT TOUCHING BLOWER WHEELS.
Immediately verify that the electrical rating nameplate located on the
cover matches electrical power supply available. Retain the shipping
carton(s) until the unit(s) are installed and properly operating.
ACCESSORIES: If the unit(s) were ordered with optional electrical acces-
sories (door switch, control panel, etc.), the accessories may be found in
the carton containing the unit or in a separate carton(s) accompanying
the unit(s). Check all of the cartons/skids for accessories before discard-
ing.
II. MOUNTING INSTRUCTIONS (General)
INDOOR MOUNTING - Environmental/Insect Dust Control
OUTDOOR MOUNTING (Unheated Only) - Insect/Dust Control
The Aristocrat/Star Air Door is designed to be an effective barrier against
cold drafts in the winter and hot air in the summer. To achieve optimum
protection, the unit should be mounted on the inside of the building,
flush to the wall and as close to the top of the door opening as possible.
To ensure peak performance keep air stream free of obstructions.
The Air Door will not perform properly if negative air pressure exists
in the building. Under these conditions, a means for makeup air to
the building must be provided so that the air pressure on both sides
of the opening is in balance.
Before mounting the unit, check the supporting structure to verify that
it has sufficient load-carrying capacity to support the weight of the
unit(s). The mounting hardware (supplied by others) should be capable
of supporting a minimum of three (3) times the weight of the unit. See
Table 1.
Model
ASF/STF 1036
ASR/STR/ASN/STN 1036
ASF/STF 1042
ASR/STR/ASN/STN 1042
ASF/STF 1048
ASR/STR/ASN/STN 1048
ASF/STF 1060-2
ASF/STF 1060-3
ASR/STR/ASN/STN2060
ASR/STR 1060
ASF/STF 1072
ASF/STF 2072
ASR/STR/ASN/STN 2072
TABLE 1 - Unit Weight
Net Weight
Net Weight
Amient
Electric
(lbs)
(lbs)
50
55
52
57
52
57
54
59
54
59
56
61
56
61
60
65
70
75
58
63
70
75
80
85
84
89
FIGURE 1 - Air Stream
NOTE: The Air Door is weatherproof, therefore no special covering is
required for outdoor mounting.
IMPORTANT: A minimum of 4" is recommended above the top of the Air
Door for the installation and removal of the cover housing.
A. When determining the mounting location for the unit(s), make sure
that nothing interferes with the curtain of air developed when the
discharge vanes are directed from 0° to 20° toward the door opening.
If the air stream strikes any obstruction (the top edge of the doorway,
a door opening device, etc.), the effectiveness of the unit will be
greatly reduced. See Figure 1.
B. For optimum performance, the bottom of the unit (discharge nozzle)
should be no more than 1" above the top of the door opening with
the unit mounted flush to the wall. If the unit must be mounted
higher, it must be spaced out from the wall ³ / ₈ " for every inch the
unit is above the door opening. For optimum protection, any void
between the Air Door and the wall should be sealed along the full
length of the unit.
See Figure 2.
FIGURE 2
2