Adequate provision e.g. easily accessible soot door or doors must be provided for
sweeping the chimney and connecting fluepipe.
Hearth
The hearth should be able to accommodate the weight of the stove and its chimney if the
chimney is not independently supported. The weight of the stove is indicated in the
brochure.
The stove should preferably be installed on a non-combustible hearth of a size and
construction that is in accordance with the provisions of the current Building Regulations
Approved Document J.
The clearance distances to combustible material beneath, surrounding or upon the hearth
and walls adjacent to the hearth should comply with the guidance on the separation of
combustible material given in Building Regulations Approved Document J and also in
these stove instructions.
If the stove is to be installed on a combustible floor surface, it must be covered with a
non-combustible material at least 12mm thick, in accordance with Building Regulations
Approved Document J, to a distance of 30 cm in front of the stove and 15 cm to each side
measuring from the door of the combustion chamber.
Combustion air supply
In order for the stove to perform efficiently and safely there must be an adequate air
supply into the room in which the stove is installed to provide combustion air. The
provision of air supply to the stove must be in accordance with current Building
Regulations Approved Document J. An opening window is not appropriate for this
purpose. If it was necessary to fit a draught stabilizer due to excessive chimney draught
then attention must be paid to the permanent combustion air requirements as this will be
different as detailed in Approved Document J.
Connection to chimney
All the stoves have a choice of either rear or top flue gas connector that allows
connection to either a masonry chimney or a prefabricated factory made insulated metal
chimney in accordance with the instructions. It may be necessary to fit an adaptor to
increase the diameter of the flue to the required 150 mm section of the chimney or liner.