Adjusting the Temperature

Your new refrigerator is already factory-set to run at optimum temperatures for food safety
and should require no adjustments.
Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum
temperature of 40 degrees Fahrenheit.
Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not run
constantly at this setting. To change it, follow these instructions:
Temperature Ranges from ( 7 ) Coldest to ( 1 ) Warmest
set
Digital Control Units
Hold "SET" for 1 sec. The display will flash the current minimum temperature.
Use the arrow buttons to adjust the minimum temperature you want it to run at.
Press "SET" again to save your settings.
Always remember to calculate the differential if you change the minimum temperature setting. The cabinet
temperature will fluctuate up to +7 degrees over your set minimum temperature as the compressor runs and
shuts off. Setting the temperature too high will result in unsafe maximum temperatures and possible health
code violations.
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to
run a manual defrost cycle at any time, please follow the steps below:
1. Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds.
2. Repeat to stop the defrost cycle.
Defrost System:
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime,
the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-off water is drained into the
evaporator pan and evaporated. Automatic defrost timers automatically initiate at pre-set intervals and for a
pre-determined duration.