Operating Instructions

1. Refer to the Serial Plate for electrical requirements. These cabinets are rated at 120V 1500W and must be plugged
into a dedicated grounded 120V 15 or 20 Amp outlet.
NOTE: modification of cord and plug will void warranty and may cause the unit to be inoperable.
2. Ensure the power switch is OFF and plug into appropriate outlet.
3. Fill the water pan to 1/2 from the top with clean HOT tap water for Proofing or if moisture is desired for Holding.
NOTE: Check water level every 3 hours (3 hours when Poorifing) and refile with clean HOT tap water as necessary.
NOTE: water pan does not have to be used/filled for heating applications that do not require moisture.
NOTE: Proofing mode requires use of water pan to be filled.
CONTROL PANELS
A
B
HEATING/HOLDING INSTRUCTIONS
1. Set HEAT/PROOF Switch (D) to HEAT.
2. Set POWER switch (A) to the ON position. Power indicator light will turn on.
3. Set TEMPERATURE control (C) to 9.
4. Pre-heat cabinet until desired temperature is reached (typical heat-up time from 77°F (25°C) ambient to 160°F (71°C)
is approximately 45 minutes). Cabinet temperature reaches 185°F (85°C) within approximately 45 minutes.
5. Re-set TEMPERATURE control (C) and adjust as necessary to reach desired temperature (setting
6-8 is typical for 150°F (66°C) to 160°F (71°C).
6. Adjust HUMIDITY control (E) to desired level. (9 being the highest, 1 the lowest, OFF being no heat to the water)
PROOFING INSTRUCTIONS
1. Set HEAT/PROOF Switch (D) to PROOF.
2. Set POWER switch (A) to the ON position. Power indicator light will turn on.
3. Set TEMPERATURE control (C) to 2.
4. Set HUMIDITY control (E) to 9.
5. Pre-heat cabinet until desired temperature and humidity is reached (typical heat-up time from 77°F (25°C) ambient to
95°F (35°C) and 95% relative humidity is approximately 30 minutes).
6. Adjust HUMIDITY control (E) to desired level. (9 being the highest, 1 the lowest, OFF being no heat to the water)
NOTE: Settings will need to be adjusted as necessary to reach desired temperature and humidty levels.
NOTE: The internal air circulation blower and 1500W heating element (controlled with the Heat Thermostat) will oper-
ate continuously when the power switch is turned ON.