Compressor is Not Running
Fuse blown or circuit breaker tripped.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Condensing Unit Runs for Long Periods of Time
Excessive amount of warm product placed in cabinet.
Prolonged door opening or door ajar.
Dirty condensor coil.
Evaporator coil iced over.
Cabinet Temperature is too Warm
Thermostat is set too warm.
Airflow is blocked.
Excessive amount of warm product placed in the cabinet. Allow adequate time for product to cool down.
Fust blown or circuit breaker tripped.
Dirty condensor coil.
Prolonged door opening or door ajar.
Replace fuse or reset circuit breaker.
Plug in power cord
Set thermostat to lower temperature.
Wait for defrost cycle to finish.
Allow adequate time for product to cool down.
Ensure doors are closed when not in use. Avoid opening
doors for long periods of time.
Clean the condensor coil.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door gasket(s)
are sealing properly.
Set thermostat to lower temperature.
Re-arrange products to allow for proper air flow. Make
sure there is at least four inches of clearance from the
evaporator.
Replace fuse or reset circuit breaker.
Clean the condensor coil.
Ensure doors are closed when not in use. Avoid opening
for long periods of time.