< 6 l/hr), the pump switches off completely. When the leakage on the
pressure side is eliminated, the pump must be unplugged and plugged in
again in order to be operational again.
Stop valve:
The integrated stop valve closes as soon as no more water is drawn.
Thermal protection switch:
In the event of an overload, the pump is switched off by the built-in
thermal motor protection. After sufficient cooling of the motor, the pump
is operational again.
4. STORAGE
To put into storage:
v Store the pump away from frost before the first frost sets in.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.
5. MAINTENANCE
Clean inlet filter and suction foot [ Fig. M1 ]:
DANGER! Electric shock!
There is a risk of injury from electric shocks.
v Before maintenance, disconnect the submersible pressure
pump from the mains.
6
1. Turn out the 8 screws
with a screwdriver.
7
2. Remove the suction foot
from the pump.
8
3. Remove the inlet filter
and the spacer ring
4. Clean the suction foot
7
, inlet filter
5. Place the spacer ring
9
onto the pump in such as way that tab
fits into the hole in the pump.
8
6. Put the inlet filter
onto the pump.
7. Put the suction foot
7
onto the pump and screw in the 8 screws
For safety reasons, a damaged turbine must only be replaced by
GARDENA Service.

6. TROUBLESHOOTING

DANGER! Electric shock!
Es besteht Verletzungsgefahr durch elektrischen Strom.
v Vor dem Beheben von Störungen die Tauch­Druckpumpe vom
Netz trennen.
Problem
Possible Cause
The pump does not deliver
Air cannot escape as the
any water
pressure line is closed.
Air cushion in suction foot.
Inlet filter or suction foot
blocked.
Pump overheated:
Thermal protection switch
switched pump off due to
overheating.
Lack of water:
Dry run protection switched
the pump off due to
insufficient water level.
8
9
from the pump.
8
and the spacer ring
9
.
0
6
.
Remedy
v Open pressure line (e. g. bent
pressure hose).
v Unplug mains cable and plug
in again.
v Disconnect mains plug, clean
inlet filter and suction foot
(see 5. MAINTENANCE).
v Disconnect mains plug, clean
inlet filter and suction foot
(see 5. MAINTENANCE).
Observe max. media tempera-
ture (35 °C).
The pump is only operational
when it is submerged at least
12 cm.
v Submerge pump at least
12 cm in water.
Problem
Possible Cause
The pump does not deliver
Leakage on the pressure side:
any water
Flow control switched the
pump off (flow < 6 l/hr).
Power supply interrupted.
Stop valve jammed.
Delivery rate suddenly
Inlet filter or suction foot
decreases
blocked.
Lack of water:
Dry run protection switched
the pump off due to
insufficient water level.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.

7. TECHNICAL DATA

Submersible Pressure Pump Unit
Rated Power
W
Max. delivery capacity
l/h
Max. pressure
bar
(= switch-off pressure)
Max. delivery height
m
Switch-on pressure
bar
Max. submersion depth
m
Power cable
m
Pump connection
mm
Minimum submersion depth
cm
on commissioning
Weight without cable
kg
(approx.)
Fastening rope
m / mm
Max. media temperature
°C
Mains voltage /
V / Hz
Mains frequency
Sound power level L
dB(A)
1)
WA
Measuring process complying with:
60335-1
1)
8. ACCESSORIES
GARDENA 2- / 4-Way Valve
For parallel connection for more than one hose
or connected devices.
GARDENA Hose Clamp
For 25 mm (1" ) hoses via the connection nipple. Art. 7192
GARDENA Hose Clamp
For 19 mm (³⁄₄" ) hoses via the connection nipple. Art. 7191
GARDENA
For 13 mm (¹⁄₂" ) hoses via the GARDENA
Pump Connection Set
Connection System.
GARDENA Tap Connector
For 16 mm (⁵⁄₈" ) hoses via the GARDENA
GARDENA Hose Connector
Connection System.
GARDENA
For 19 mm (³⁄₄" ) hoses via the GARDENA
Pump Connection Set
Connection System.
9. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty:
In the event of a warranty claim, no charge is levied to you for the services
provided.
GARDENA Manufacturing GmbH offers a two-year warranty (effective
as of the date of purchase) for this product. This warranty includes all
significant defects of the product that can be proved to be material or
manufacturing faults. This warranty is fulfilled by supplying a fully func-
Remedy
v Check pressure hose and all
consumers on the pressure
side for tightness. Unplug
pump and plug in again.
v Check fuses and electrical
plug-in connections.
v Flush outlet area with clear
water and free stop valve.
v Disconnect mains plug,
clean inlet filter and suction
foot (see 5. MAINTENANCE).
The pump is only operational
when it is submerged at least
12 cm.
v Submerge pump at least
12 cm in water.
Value (Art. 1476)
1050
6000
4.5
45
2.6 ± 0.2
12
15 H07RN-F
33.3 (G 1" female thread)
12
8.0
15 length / ∅ 5
35
230 / 50
46
Art. 1210 / 1194
Art. 1750
Art. 18202
Art. 18216
Art. 1752