Gardena 1777 Instrukcja obsługi - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Gardena 1777. Gardena 1777 12 stron. Submersible pump/dirty water pump

Gardena 1777 Instrukcja obsługi

5. Storage

Storage:
Disposal:
(in accordance with
RL2002/96/EC)

6. Cleaning

Flushing the pump:
Cleaning the suction
base and feed impeller:
©
©
©
k
©
s
©
©

7. Troubleshooting

Problem
Pump is running,
but oes not deliver.
14
➜ Clean and store the pump in a frost-free place before the first
frost arrives.
The product must not be added to normal household waste.
It must be disposed of in line with local environmental regulations.
The GARDENA should not require regular maintenance.
After pumping pumped chlorinated swimming pool water or other
liquids leaving residues, the pump should be rinsed with clear
water.
WARNING ! Electric shock !
Risk of injury due to electric shock.
➜ Disconnect the pump from the mains before
cleaning the suction base and feed impeller.
1. Unscrew the cross-head screws
base
from the pump.
2. 6000 SP: Press snap hooks k s together and remove safety
cover
from suction foot
3. Clean suction foot
4. Refit suction foot
again. During this, ensure that the sealing ring
correctly.
5. 6000 SP: Reinsert the safety cover
again.
For safety reasons a damaged feed impeller
exchanged by the GARDENA Service Centre.
WARNING ! Electric shock !
Risk of injury due to electric shock.
➜ Disconnect the pump from the mains before
rectifying faults.
Probable cause
Air cannot escape as
pressure line is closed.
Air locks in the suction base.
and remove the suction
and clean.
and impeller
.
and screw in the cross-head screws
in the suction foot
Remedy
➜ Open pressure line
(e.g. kinked pressure pipe).
➜ Wait for max. 60 seconds
until the pump deaerates
automatically over the vent
valve. If necessary, switch
off and start it again.
is seated
can only be