Gardena 9045 Instrukcja obsługi - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Gardena 9045. Gardena 9045 14 stron. Dirty water submersible pump

Gardena 9045 Instrukcja obsługi

4. MAINTENANCE

DANGER! Risk of injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before
you maintain the product.
To clean the pump:
DANGER! Risk of injury!
Risk of injury and risk of damage to the
product.
v Do not clean the product with a water jet
(in particular high-pressure water jet).
v Do not clean with chemicals including petrol or
solvents. Some can destroy critical plastic parts.
v Clean the surface of the pump with a damp cloth.

5. STORAGE

To put into storage:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water
runs out.
3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.

6. TROUBLESHOOTING

DANGER! Risk of injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before
you troubleshoot the product.
To clean the suction base and the impeller [ Fig. T1 ]:
1. Unscrew the 5 Phillips screws
(10)
cover
.
2. Unscrew the 4 Phillips screws
Problem
Pump is running, but doesn't
deliver water
14
(9)
and remove the
(6)
.
Possible Cause
Air cannot escape, because the
pressure line is closed.
(Possible kink in the pressure hose.)
Air in suction foot.
Suction opening is clogged.
To flush the pump:
After pumping water containing chlorine, detergents or
heavily soiled water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding
a mild cleaning agent (e. g. detergent) until the pumped
water runs clear.
2. Remove residuals according to the waste disposal laws
applicable in your area.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal
household waste. It must be disposed of in line
with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal
recycling collection centre.
(7)
3. Pull the suction base
4. Clean suction base
(7)
and impeller
does not become void as a result of this maintenance
work).
5. Clean the sealing surfaces carefully to avoid damage
and leakage.
6. Reassemble the suction base
A damaged seal must be replaced.
For safety reasons a damaged impeller can only be
exchanged by the GARDENA Service Centre.
Remedy
v Open the pressure line
(e. g. shut-off valve, delivery units).
v Wait for about 60 seconds until the
pump has vented; if necessary, turn
off and then on again.
v Clean the suction opening with
a water jet.
off the pump.
(8)
(the warranty
(7)
in reverse order.