Gardena FFP 5000 Instrukcja obsługi - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Gardena FFP 5000. Gardena FFP 5000 10 stron. Underwater filter with fountain pump set
Również dla Gardena FFP 5000: Instrukcja obsługi (11 strony)

Gardena FFP 5000 Instrukcja obsługi
Cleaning the Fountain Insert :

6. Trouble-shooting

Cleaning the Pump:
H
I
Fault
No water feature operating
Reduced water feature
Pump shuts down after
a short time
If any other faults arise, please contact GARDENA Service.
7. Storing your Fountain Pump Set
Overwintering :
1. Unscrew fountain insert
2. Wash out the nozzle tube and fountain insert
Warning ! Electric shock !
A
V Please unplug the pump before carrying out
any maintenance works.
1. Remove the pump from the filter block (see 5. Maintenance).
2. Turn the pump housing
off the motor housing
3. Pull the impeller
4. Push the cleaned impeller
5. Press the pump housing
H
and turn it clockwise. (Bayonet fastening).
6. Reassemble the pump into the filter block (see
G
5. Maintenance).
Possible cause
Mains plug not plugged in.
Impeller unit is blocked.
Electronic circuit breaker
has been activated.
Water feature insert is dirty.
Filter clogged.
Water temperature too high.
The pump should be stored out of the reach of children.
1. Remove the Filter and Fountain Pump from the pond before frost
is expected and clean.
2. To avoid difficulties when starting up in the spring, we recom-
mend storing the pump in a frost-free location in a container
filled with water.
The mains plug must not be submerged.
3
from the nozzle tube
G
anticlockwise and pull it vertically
H
(Bayonet fastening).
I
out of the motor housing
I
back into the motor housing
G
vertically on to the motor housing
Remedy
v Plug in mains plug.
v Clean pump.
v Stand the pump in the
water.
v Clean water feature insert.
and nozzle pipe.
v Clean filter.
v Maximum water
temperature is 35 °C.
1
.
3
in clean water.
H
and clean it.
H
.
11