Electrical
requirements
Electrical Shock Hazard
Electrical Shock Hazard
l
Electrical ground is required on this
l
Electrical ground is required on this
appliance.
appliance.
l
Do Not ground to a gas pipe.
l
Do Not have a fuse in the neutral or
grounding circuit. A fuse in the neutral or
grounding circuit could result in an
electrical shock.
l
Check with a qualified electrician if you
are in doubt as to whether the appliance is
properly grounded.
l
Do Not connect to the electrical supply
until appliance is permanently
grounded.
l
Disconnect power to the junction box
before making the electrical
connection.
Failure to follow these instructions
could
result in serious injury or death.
l
This appliance must be connected to a
grounded, metallic, permanent wiring
system, or a grounding connector
should be connected to the grounding
terminal or wire lead on the appliance.
Failure to do so could result in a fire,
personal injury or electrical shock.
If codes permit and a separate grounding wire
is used, it is recommended that a qualified
electrician determine that the grounding path
is adequate.
*
Save Installation
Instructions
for the local
(A
This appliance must be connected to the
n
proper electrical voltage and frequency
as specified on the serial/rating
plate. Models
rated at
15.0 kw
on 240 volts (11.25 kw on
208 volts) or more require a separate 50-ampere
circuit. Models rated at less than 15.0 kw on 240
volts (11.25 kw on 208 volts) or less require a
separate 40-ampere circuit. Fuse both sides of
the line. A time-delay fuse or circuit breaker is
recommended.
El
I
Locate the junction box to allow as
much slack in the cable as possible
Electrical
connection
OVEN MUST BE CONNECTED
WITH
SOLID COPPER WIRE ONLY.
El
Wire sizes and connections
must
n
conform to the requirements
of the
National Electrical Code, ANSI/NFPA
70 -
latest
edition**, and all local codes and ordinances for
the kilowatt rating of the oven. Wires sizes and
connections
must conform with the rating of the
oven. This rating can be found on the seriavrating
plate located on the front frame behind the
microwave oven door or lower oven door.
Copies of the standards listed may be obtained
from:
**National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
This appliance should be connected
directly to the fused disconnect
(or
circuit breaker box) through flexible, armored or
non-metallic
sheathed, copper cable (with
grounding wire). The flexible armored cable
extending from the appliance should be
connected directly to the junction box.
between the junction box and the appliance so
that the oven can be moved if servicing is ever
necessary.
Do Not cut the conduit.
h
*
El
A U.L.-listed conduit connector
must
be
w provided at the junction box.
A wiring diagram is included in the Tech
Sheet. The Tech Sheet is located
behind the oven control panel.
This appliance is manufactured
with white
(neutral) power supply wire and a cabinet-
connected, green grounding wire twisted
together.
Connect the appliance cable to the junction box
through the U.L.-listed conduit connector.
Complete electrical connection according to local
codes and ordinances.
A. Where local codes permit...
Connecting the cabinet-grounding
conductor
to the neutral (white) junction box wire:
cable from
'unction
b
power supply
ox \
I
I
bare or
green wire
F
U.L.-listed
conduit
Figure I
cable from
connector
oven
Grounded neutral
1. Disconnect the power supply.
2. Remove the terminal block cover.
3. Connect together 3 wires: green and white
appliance cable wires and the neutral (white)
wire in junction box.
4. Connect the two black wires together; then the
two red wires together. See Figure 1.
B. Where local codes Do Not
permit...
Connecting the cabinet-grounding
conductor
to the neutral (white) junction box wire:
junction
box.
cable from
power supply
white
bare or
green
wires
wires
cable from
conduit
Figure 2 Oven
connector
Ungrounded neutral
1. Disconnect power supply.
2. Separate the green and white appliance cable
wires.
3. Connect the white appliance cable wire to the
neutral (white) wire in the junction box.
4. Connect the two black wires together; then the
two red wires together. See Figure 2.
5. Connect the green or bare grounding wire from
the appliance cable to a grounded wire in the
junction box.
C. If connecting
to a four-wire
electrical
system...
Do Not connect the cabinet-grounding
conductor to the neutral (white) junction box
wire.
junction
box.
cable 1 'ram
power
_ _,~ r.,
SUDBIV
.
.
green
wires
ite
es
:k w rires
Figure 3
connector
1. Disconnect the power supply.
2. Separate the green (or bare) and white
appliance cable wires.
3. Connect the white appliance cable wire to the
neutral (white) wire in the junction box.
4. Connect the two black wires together; then the
two red wires together. See Figure 3.
5. Connect the green appliance cable wire to the
green grounding wire in the junction box.
Now start...
With oven in kitchen.
(II
Remove shipping materials, tape, and
protective film from microwave oven and
.
oven.
Do Not remove shipping base at
this time.
Remove and unwrap the racks and other
parts from inside the oven. Remove the
air grille'taped to top or side of oven.
l
Use both hands to remove oven door.
. Grasp only the sides of oven door.
l
Do Not use handle or any portion of the
front frame or trim for lifting.
l
Because of the weight and size of the
oven, two or more people are needed to
lift, move and safely install the oven.
Failure to properly grasp the oven door or
to lift oven properly could result in damage
to the product or personal injury.
1 Personal Injury/Property
Damage Hazard
Insert a nail (or equivalent,
5/32" diameter item)
into the hole in each of the hinges. Close the
oven door as far as possible. Lift the oven door
off of the hinges. Set aside.
Property Damage
Before moving oven across floor, check
that oven is on shipping base or slide
oven onto cardboard or hardboard.
Failure to follow these instructions
may
result in damage to floor covering.
Turn power supply off. Move oven close
to final position. Remove and discard
shipping base or cardboard or hardboard. Feed
appliance cable through the opening in cabinet.
Make electrical connection.
See "Electrical
requirements"
and "Electrical connection"
sections, Panel B.
Panel B