Reset
The factory settings are restored.
v Press ▲-key and O.K.-key simultaneously for 2 seconds.
All the LCD symbols are displayed for 2 seconds and the
display moves to the normal display.
• All the program data are set to zero.
• The manual watering period is set to
• The time and day of the week are retained.
Important notes :
If no entry is made during programming for a period of more
than 60 seconds, the normal display reappears.
With overlapping programs and identical watering days, the
st
1
watering starting time has priority and other programs are
not initiated.
Example :
Program
Starting time
Watering time
PROG
START TIME
RUN TIME
1
4 : 00
0: 40
4 : 30
1 : 00
2
nd
The first program is run on Monday, the 2
program is cancelled.
18
0 0 : : 3 3 0 0
again.
Watering days / Watering cycles
nd
Mo
Tu
We
Th
Fr
Sa
So
2
X
X
X

6. Automatic Water Distributor (optional)

Function
Programming
Special function
rd
3
Connecting the GARDENA Automatic Water Distributor
(Art. No. 1198) allows you to control up to 6 watering lines with
the Water Computer C 1060 profi.
Each of the 6 watering lines can only be actuated once a day.
This is ideal where there is an insufficient amount of water or
where individual areas of the garden have varying water require-
ments. It allows all watering lines to be operated one after
another.
Using the special function, your Water Computer C 1060 profi is
able to take into account the special requirements of the Automatic
Water Distributor, when programming.
If program data have already been inserted beforehand, a RESET
must be undertaken before the special function can be set.
v Keep ▲-key and O.K.-key pressed simultaneously for
2 seconds.
To ensure the Automatic Water Distributor switches safely there
must be at least a 30 minute break between the programs entered
in the Water Computer.
When you have confirmed the special function with O.K. and
have entered the data for the first program (see 5. Programming )
all the programmes which follow will be pre-programmed auto-
matically.