The microwave
oven must be installed on a minimum
of 1 wall
stud, preferably 2, using a minimum
of 1 lag screw, preferably 2.
1.
Using measuring
tape, find and clearly mark the vertical
centerline
of the opening.
.....................
;....................................
A. Centerline
2. With the support tabs facing forward (see illustrations in
"Possible Wall Stud Configurations"
in "Locate Wall Stud(s)"
section), align the mounting plate center markers to the
centerline on the wall, making sure it is level, and that the top
of the mounting plate is butted up against the bottom edge of
the upper cabinet.
NOTE: If the front edge of the upper cabinet is lower than the
back edge, lower the mounting plate so that its top is level with
the front edge of the cabinet.
A
.............................
J
C
...............................
S
A. Rear wall
B. Mounting plate
C. Top of mounting plate must align
with front edge of cabinet.
D. Front edge of upper cabinet
3.
4.
Holding the mounting plate in place, mark both bottom corner
holes.
Find the wall stud centerline(s) marked in Step 2 of "Locate
Wall Stud(s)," and mark at least 1, preferably 2, hole(s) through
the mounting plate, closest to the wall stud centerline(s). See
figures 1,2 and/or 3 in "Possible Wall Stud Configurations"
in
"Locate Wall Stud(s)" section. The blackened holes in the
shaded areas are ideal hole locations.
5. Set the mounting plate aside.
Wall Venting Installation Only
Upper cabinet bottom
I
t
4" (10.2 era)
d¢
CenterJine
.
6" (15.2 cm)
6" (15.2 cm)
6. Mark the centerline 3/8" (1 cm) down from the bottom edge of
the upper cabinet.
7=
8.
9.
10.
11.
12.
Using measuring tape, measure out 6" (15.2 cm) on both sides
of the centerline, and mark.
Measure down 4" (10.2 cm) from the mark made in Step 6,
and mark.
Using a straightedge, draw the 2 horizontal, level lines through
the marks made in steps 6 and 8.
Draw the 2 vertical, plumb lines down from the marks made in
Step 7 to complete the 12" x 4" (30.5 x 10.2 cm) rectangle.
This is the venting cutout area.
Cut a 3/4" (19 mm) hole in one corner of the cutout area.
Using a keyhole saw, cut out the venting cutout area.
L_;;S<i}@8_ " sj%,
In addition to being installed on at least 1 wall stud, the mounting
plate must attach to the wall at both bottom corner holes. If the
holes are not over wall studs, use two 1/4-20 x 3" round-head
bolts with toggle nuts; if 1 hole is over a wall stud, use 1 lag screw
and one 1/4-20 x 3" round-head bolt with toggle nut; or if both
holes are over wall studs, use 2 lag screws. Following are
3 installation configurations.
Installation for No Wall Studs at Corner Holes
(Figures I & 2)
1=
2.
Drill 3/4" (19 mm) holes through the wall at both bottom corner
holes marked in Step 3 of "Mark Rear Wall."
Drill 3/16" (5 mm) hole(s) into the wall stud(s) at the hole(s)
marked in Step 4 of "Mark Rear Wall." Refer to figures 1 and 2
in "Possible Wall Stud Configurations"
in "Locate Wall Stud(s)"
section.
Installation for Wall Stud at One Corner Hole (Figure 3)
1. Drill a 3/16" (5 mm) hole into the wall stud at the corner hole
marked in Step 3 of "Mark Rear Wall."
2. If installing on a second wall stud, drill a 3/16" (5 mm) hole into
the wall stud at the other hole marked in Step 4 of "Mark Rear
Wall." Refer to Figure 3 in "Possible Wall Stud Configurations"
in "Locate Wall Stud(s)" section.
3. Drill a 3/4" (19 mm) hole through the wall at the other corner
hole.
Installation for Wall Studs at Both Corner Holes
(Figure 4)
1. Drill 3/16" (5 mm) holes into the studs at the corner holes
marked in Step 3 of "Mark Rear Wall."
NOTF: Secure the mounting plate to the wall at both bottom
corner holes drilled into the wall studs and/or drywall using either
1/4-20 x 3" round-head bolts and toggle nuts or 1/4 x 2" lag
screws.
Refer to illustrations in "Possible Wall Stud Configurations"
in
"Locate Wall Stud(s)" section.
No Wall Studs at Corner Holes (Figures I & 2)
NOTE: The mounting plate must be secured to the wall on at least
1 wall stud as well as at both bottom corners.
1. With the support tabs of the mounting plate facing forward,
insert 1/4-20 x 3" round-head bolts through both bottom
corner holes of mounting plate.