ACCESSING THE SETUP MENU
Setup menu
MMA welding
CHANGING WELDING PARAMETERS
Turn and press the adjusting dial to select and change parameters.
PARAMETERS FOR MMA WELDING
Starting current duration: 0.1 - 1.5 seconds |
0.5 seconds*
Anti-stick: On* / OFF
Start ramp: On* / OFF
Break voltage: 25 - 90 V | 45 V*
Factory setting
Level 2 Setup menu
WELDING PARAMETERS IN THE LEVEL 2 SETUP MENU
Software version
Automatic switch-off: 5 - 60 minutes / OFF*
Fuse: 230 V = 10 A, 13 A, 16 A* /
120 V = 15 A, 16 A, 20 A*
Operating time: hours, minutes, seconds
Welding time: hours, minutes, seconds
ACCESSING THE SETUP MENU
Setup menu
MMA welding
CHANGING WELDING PARAMETERS
Turn and press the adjusting dial to select and change parameters.
PARAMETERS FOR MMA WELDING
Starting current duration: 0.1 - 1.5 seconds |
0.5 seconds*
Anti-stick: On* / OFF
Start ramp: On* / OFF
Break voltage: 25 - 90 V | 45 V*
Factory setting
Level 2 Setup menu
WELDING PARAMETERS IN THE LEVEL 2 SETUP MENU
Software version
Automatic switch-off: 5 - 60 minutes / OFF*
Fuse: 230 V = 10 A, 13 A, 16 A* /
120 V = 15 A, 16 A, 20 A*
Operating time: hours, minutes, seconds
Welding time: hours, minutes, seconds
Setup menu
Cel electrodes
PARAMETERS FOR TIG WELDING
Operating mode: OFF / 2-step* / 4-step
Starting current: 1 - 200 % | 50 %*
Reduced current: 1 - 200 % | 50 %*
Final current: 1 - 100 % | 50%*
Gas post-flow time: 0.2 - 9.9* seconds
Comfort Stop sensitivity:
TP150 = OFF / 0.5 - 2.5 V | 1.6 V*
TP180 = OFF / 0.5 - 2.5 V | 1.5 V*
Break voltage: 12 - 22 V | 15 V*
Tacking function: OFF* / 0.1 - 5.0 seconds
Factory setting
Level 2 Setup menu
Setup menu
Cel electrodes
PARAMETERS FOR TIG WELDING
Operating mode: OFF / 2-step* / 4-step
Starting current: 1 - 200 % | 50 %*
Reduced current: 1 - 200 % | 50 %*
Final current: 1 - 100 % | 50%*
Gas post-flow time: 0.2 - 9.9* seconds
Comfort Stop sensitivity:
TP150 = OFF / 0.5 - 2.5 V | 1.6 V*
TP180 = OFF / 0.5 - 2.5 V | 1.5 V*
Break voltage: 12 - 22 V | 15 V*
Tacking function: OFF* / 0.1 - 5.0 seconds
Factory setting
Level 2 Setup menu
Setup menu
TIG
* factory setting
Setup menu
TIG
* factory setting