6.3 Parameter for fillet welding in the vertical position (Please refer to the following figure.)
Plate thickness
Corn size
t(mm)
I (mm)
1.2
2.5~3.0
2.5~3.0
1.6
3.0~3.5
2.0
3.0~3.5
2.3
3.0~4.0
3.2
4.0~4.5
4.5
6.4 Parameter for Lap Welding (Please refer to the following figure.)
Plate thickness
Corn size
t(mm)
I (mm)
0.8
1.2
1.6
A or B
2.0
2.3
3.2
4.5
Wire
Welding current
φ(mm)
1.0
1.0 ~ 1.2
1.0 ~ 1.2
1.0 ~ 1.2
1.0 ~ 1.2
1.2
Wire
Welding current
φ(mm)
A
0.8~0.9
A
1.0
A
1.0 ~ 1.2
1.0 ~ 1.2
B
1.0 ~ 1.2
B
1.0 ~ 1.2
B
1.2
Welding
(A)
voltage (V)
70~100
18~19
90~120
18~20
100~130
19~20
120~140
19~21
130~170
22~22
200~250
23~26
Welding
(A)
voltage (V)
60~70
16~17
80~100
18~19
100~120
18~20
100~130
18~20
120~140
19~21
130~160
19~22
150~200
21~24
Welding speed
Gas volume
(cm/min)
(L/min)
50~60
10~15
50~60
10~15
50~60
10~20
50~60
10~20
45~55
10~20
45~55
10~20
Welding speed
Gas volume
(cm/min)
(L/min)
40~45
10~15
45~55
10~15
45~55
10~15
45~55
15~20
45~50
15~20
45~50
15~20
40~45
15~20
14