A-Collection KD-122LA Instrukcja instalacji - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Alarm dymowy A-Collection KD-122LA. A-Collection KD-122LA 15 stron. Wireless interconnected smoke alarm
5. Installation
5.1 Functional diagram (Figure 2)
Buzzer
Alarm indication
Test/Hush Button
Slot
Positioning Column
Screw hole
Battery -
Hook
Battery +
EN
Wireless Signal Indicator
Learn Button
Slot
Battery Pin -
Battery Pin +
Hook
Positioning Groove
Screw hole
5.1 Functional diagram (Figure 2)
a Hold the mounting plate against the selected installation position on the ceiling, and mark the center of the
holes with a pencil. Drill a hole through the pencil marks and use the enclosed screws and anchors to secure
the mounting plate. (See Figure 4)
b. Insert the hook of the mounting plate to the slot of the alarm, the positioning column should also align with
the positioning groove. Rotate the alarm clockwise until it snaps into place.
Figure 4
c. You can move the alarm to a new location by rotating the alarm counter-clockwise, then removing the
screws and repeating the instructions from 5.2 a in the new location.
Note: If you can't rotate the alarm after insect the hook into the slot, please check if the positioning
column aligns with the positioning groove.
Note: if you need to close/open the installation plate to test the smoke alarm before install to
ceiling,please hold the plate by heart of palms to operate.
5.3 Recommended Locations for Smoke Alarms and Locations to Avoid
a. Recommended Locations for Smoke Alarms
• Install at least one smoke alarm in every bedroom
• If you install the smoke alarm in a passageway whose width is less than 3 m, install it in the middle and
install one unit every 12 m.
• At least 1.5 m from fluorescent lamp or neon lamp. (In case of electronic interference).
• At least 3 m from the bathroom.
• At least 6 m from the kitchen or stove.
• At least 30 cm from the lamps.
• Locate the smoke alarm in the middle of the room. If you can't, install it at least 1 m from the wall.
• If you install the smoke alarm on sloped or peaked ceiling, the installation position shall be at least 90cm
from the highest point.
correct location
wrong location
EN
do not install the
smoke alarm here