Garmin GHP 10 Marine Autopilot System Instrukcja instalacji - Strona 14

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Morski system GPS Garmin GHP 10 Marine Autopilot System. Garmin GHP 10 Marine Autopilot System 48 stron. Tachometer reference
Również dla Garmin GHP 10 Marine Autopilot System: Skrócona instrukcja obsługi (21 strony), Instrukcja instalacji (26 strony), Informacje techniczne (42 strony), Deklaracja zgodności (1 strony), Odniesienie (1 strony)

Garmin GHP 10  Marine Autopilot System Instrukcja instalacji
Compact 2.1 L Pump Hydraulic Layout on SeaStar Power Assist-Enabled Boats
Balanced cylinder
Starboard fitting
Starboard line
Port line
C1
C
Sea Star
Power Assist
module
H1
H
Port line
Return line
Starboard line
1
Port fitting
Return line
Helm
P
R
Shadow Drive
notes:
S
Do not turn the system on until you bleed all
the air from the helm, the Shadow Drive, the
pump, and all the hydraulic lines. See
GHP 10 Marine Autopilot System Installation Instructions
Power Assist module:
It may be necessary to remove the
Power Assist module to gain access to
the fittings, the hoses, and the bleed-tee
fitting
You may need to add a tee fitting in the
return line at the Power Assist module
to connect the pump.
Compact 2.1 L pump (and motor):
Install the pump to the steering lines
between the cylinder and the Power
Assist module.
Do not install the pump to the
steering lines between the helm and
the Power Assist module.
to use the compact 2.1 L pump on a
system with an unbalanced cylinder,
follow the procedures on
Mount the pump horizontally if
possible. Do not mount the pump
vertically with the pump end (hydraulic
connections) down.
Shadow Drive:
Mount the Shadow Drive horizontally
and as level as possible.
Install the Shadow Drive in either the
port or the starboard hydraulic steering
line.
Always install a length of hose between
the helm and the Shadow Drive.
Install the Shadow Drive between the
helm and the Power Assist module.
Do not install the Shadow Drive
directly to the helm.
Do not install the Shadow Drive
between the Power Assist module and
the pump.
Do not install the Shadow Drive
between the Power Assist module and
the cylinder.
Notice
page
24.
page
34.