Fujitsu ACY71UIA-LM Instrukcja obsługi - Strona 17
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Klimatyzator Fujitsu ACY71UIA-LM. Fujitsu ACY71UIA-LM 17 stron. Duct type
OPERATING TIPS
Instructions relating to inverter (
AUTO Restart
In Event of Power Interruption
Should the power supply to the air conditioner be interrupted
l
by a power failure, the air conditioner will restart automatically
in the previously selected mode once the power is restored.
Multi-type Air Conditioner
This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated
in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.
Simultaneous Use of Multiple Units
When using a multi-type air conditioner, the multiple indoor
l
units can be operated simultaneously, but when 2 or more
indoor units of the same group are operated simultaneously,
the heating and cooling effi ciency will be less than when a
single indoor unit is used alone. Accordingly, when you wish
to use more than 1 indoor unit for cooling at the same time,
the use should be concentrated at night and other times
when less output is required. In the same way, when multiple
units are used simultaneously for heating, it is recommended
that they be used in conjunction with other auxiliary space
heaters, as required.
Seasonal and outdoor temperature conditions, the structure of
l
the rooms and the number of persons present may also result
in differences of operating effi ciency. We recommend that you
try various operating patterns in order to confi rm the level of
heating and cooling output provided by your units, and use
the units in the way that best matches your family's lifestyle.
lf you discover that 1 or more units delivers a low level
l
of cooling or heating during simultaneous operation, we
recommend that you stop simultaneous operation of the
multiple units.
Simultaneous Multi Air Conditioner
This indoor unit can also be connected to a simultaneous multi connection that enables simultaneous operation of up to 3 indoor units
with connecting the outdoor unit by using a separation tube (twin or triple).
Note: Connectable type of the separation tube varies by model.
In simultaneous multi connection, all the indoor units perform simultaneous air conditioning controlled by one controller that is specifi ed
as the primary control unit.
For this unique characteristic of the simultaneous multi connection, some of the functions controlled by the controller that is specifi ed
as the secondary control unit are restricted.
Notices
*
During use of the heating mode, the outdoor unit will occasion-
l
ally commence the defrost operation for brief periods. During the
defrosting operation, if the user sets the indoor unit for heating
again, the defrosting mode will continue, and the heating opera-
tion will begin after completion of defrosting, with the result that
some time may be required before warm air is emitted.
SELF-DIAGNOSIS
When "Er" in temperature indicator is displayed, inspection of the air conditioning system is necessary. Please consult authorized
service personnel.
) are applicable only to "INVERTER MODEL".
v
Unit number (usually "00")
ex. Self-diagnosis check
Use of other electrical appliances (electric shaver, etc.) or
l
nearby use of a wireless radio transmitter may cause the air
conditioner to malfunction. In this event, temporarily discon-
nect the power supply, reconnect it, and then use the remote
controller to resume operation.
Operation cannot be done in the following different operating modes.
v
l
If the indoor unit is instructed to do an operating mode that it
cannot perform,
display and the unit will go into the standby mode.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode
Operation can be done in the following different operating modes.
v
l
Cooling mode and dry mode
Cooling mode and fan mode
Dry mode and fan mode
The operating mode (heating mode or cooling (dry) mode)
v
l
of the outdoor unit will be determined by the operating mode
of the indoor unit that was operated fi rst. If the indoor unit
was started in fan mode, the operating mode of the outdoor
unit will not be determined. For example, if indoor unit (A)
was started in fan mode and then indoor unit (B) was then
operated in heating mode, indoor unit (A) would temporarily
start operation in fan mode but when indoor unit (B) started
operating in heating mode,
remote controller display and it would go into standby mode.
Indoor unit (B) would continue to operate in heating mode.
*
During use of the heating mode, the top of the indoor unit
l
may become warm, but this is due to the fact that coolant is
circulated through the indoor unit even when it is stopped;
it is not a malfunction.
Error code
will be shown on the re-mote controller
will be shown on the unit (A)
En-17