Fujitsu UTY-RSK Series Instrukcja obsługi
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Klimatyzator Fujitsu UTY-RSK Series. Fujitsu UTY-RSK Series 21 stron. Simple remote controller (wired type)
AIR CONDITIONER
KEEP THIS MANUAL FOR
FUTURE REFERENCE
OPERATING MANUAL
SAFETY PRECAUTIONS
•
The "SAFETY PRECAUTIONS" indicated in the operating manual contain important information pertaining
to your safety. Be sure to observe them.
•
For d
etails of the operation methods, refer to the operating manual.
•
Request the user to keep the manual on hand
This mark indicates procedures which, if improperly performed, might lead to the death or
WARNING
serious injury of the user.
•
In the event of a malfunction (burning smell, etc.),
immediately stop operation, turn off the electrical
breaker, and consult authorized service personnel.
•
Do not repair or modify any damaged cable by
yourself. Let the authorized service personnel to
do it. Improper work will cause a electric shock or a
fire.
•
This unit contains no user-serviceable parts.
Always consult authorized service personnel for
repairs.
This mark indicates procedures which, if improperly performed, might possibly result in
CAUTION
personal harm to the user, or damage to property.
•
Do not set vessels containing a liquid on this unit.
Doing so will cause heating, fire, or electric shock.
•
Do not expose this unit directly to water. Doing so
will cause trouble, electric shock, or heating.
•
Dispose of the packing materials safely. Tear and
dispose of the plastic packing bags so that children
cannot play with them. There is the danger of
suffocation if children play with the original plastic
bags.
9371069029-03_OM_en.indd 1
SIMPLE REMOTE CONTROLLER
TM
(WIRED TYPE)
P/N 9371069029-03
for future use, such as for relocating or repairing the unit.
•
When moving, consult authorized service personnel
for disconnection and installation of this unit.
•
Do not touch with wet hands. It may cause an
electric shock.
•
If children may approach the unit, take
measures so that they cannot reach the unit.
•
Do not repair or modify by yourself. It may cause a
fault or accident.
•
Do not use flammable gases near this equipment.
It may cause a fire from leaking gas.
•
Do not place electrical devices within 1 meter of
this unit. It may cause malfunction or failure.
•
Do not use fire near this unit or place a heating
apparatus nearby. It may cause malfunction.
•
Do not touch the switches with sharp objects.
Doing so will cause injury, trouble, or electric shock.
Cooling / heating priority
(AIRSTAGE™ (VRF-II Series Heat Pump model only))
•
If another indoor unit in the same system is already operating in the
cooling mode or dry mode, heating mode settings cannot be performed.
•
An indoor unit that is set up as an Administrative Indoor Unit can
operate in the AUTO mode.
•
Administrative Indoor Unit:
Special indoor unit is not restricted by the switching of cooling and
heating described above.
It may happen if the unit is set to refrigerant system setting.
English
TROUBLE SHOOTING
Before requesting service, perform the following checks:
Symptom
Doesn't
•
Has there been a power failure?
operate
•
Has a fuse blown out, or a circuit breaker been
at all.
tripped?
•
Is the main power switch set to the OFF position?
•
Is the timer operating?
If the problem persists after performing these checks, or if you notice
burning smells, or the operation lamp flashes, immediately stop operation,
turn off the electrical breaker and consult authorized service personnel.
preventive
MODEL
POWER
DIMENSION & WEIGHT
HEIGHT
WIDTH
DEPTH
WEIGHT
OPERATING TIPS
Problem
SPECIFICATIONS
UTY-RSK
DC12V
120 mm
75 mm
14 mm
UTY-RSKY/
90 g
UTY-RSKG
UTY-RSKYT
100 g
5/28/2009 2:27:51 PM