Fujitsu Primergy RX100 S5 Instrukcja obsługi - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Serwer Fujitsu Primergy RX100 S5. Fujitsu Primergy RX100 S5 9 stron.

4
Conditions
n Restriction of installation features
When installing this server, avoid the following areas.
- Humid, dusty, or oily smoke areas
- Poorly ventilated areas
- Areas close to fire or other sources of heat
- Areas close to water
- Areas close to direct sunlight or near heating appliances
- Areas with a temperature of below 10°C or above 35°C
- Areas with humidity of less than 20% or more than 80%
- Salty air environments
- Areas where corrosive gas is generated
- Areas where cables become trip hazards
- Areas where strong magnetic fields are generated, such
as near TVs and speakers
- Areas where the server is not stable and could tip over
and hurt somebody
- In dusty areas, dust will stick to the front and backside of
the server for a short period of time.
Since it causes failure, changing the installation place is
recommended.
- Noise levels of this server are measured at 45dB.
When the server is installed to e.g. an office use the
server with careful consideration to the environment.
n Install the server into the rack
Be sure to secure the rack with stabilizers to prevent the
device from tipping over. For details on installing the rack,
refer to the rack manual.
1
Open both the front and rear doors of
the rack.
2
Check that the locations where the slide
rails and rack nuts will be installed.
The slide rails are attached to the front and rear rack
pillars. The rack nuts are attached to the front pil-
lars.
��������������������
�������������������
�����������������������
��������������������������
�������������������
��������������������
������������������������
�������������
�������������
���������������������������
3
Check the right and left of the slide
rails.
[RIGHT] is stamped on the right side rail near the rack
pillar and [LEFT] is stamped on the left side rail.
4
Remove the inner rail from the slide rail.
����������������������
����������
5
Attach the inner rail to the server.
Set the screws on the server side in the holes of the
rail (1), and slide the rail backward to secure it (2).
��������������������������
6
Attach the slide rail assemblies and in-
sert the rack nuts into the rack holes.
1.
Insert the pins on the rear of the slide rails
into the rack.
2.
Align the screw location on the front of the
side rails with the rack, and attach the slide
rails to the rack along with the washers.
3.
Insert the rack nut tabs from inside of the rack
pillar to attach the rack nuts.
�������
�����������
������
������������������
2
����������
���������
�����������������������������
������������������������������������������������
���
���������������������������
������
���������������
����������
���������������
��������������
����������������
���
���