Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF Podręcznik konfiguracji - Strona 15

Przeglądaj online lub pobierz pdf Podręcznik konfiguracji dla Przechowywanie Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF. Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF 29 stron. Fibre channel/ eternus dx500 s4/dx600 s4, eternus dx500 s3/dx600 s3, eternus dx8700 s3 hybrid storage systems, eternus dx400 s2 series, eternus dx8700 s2 disk storage systems, eternus af650 s2, eternus af650 all-flash arrays settings for bs2000 connection

Fujitsu ETERNUS DX S2, ETERNUS DX S3, ETERNUS DX S4, ETERNUS AF Podręcznik konfiguracji
Chapter 4 Set Up the ETERNUS DX/AF Storage System for BS2000

4.2 Configuring Settings for the Fibre Channel Ports (CA Parameters)

TPGS Mode
Sense Data Conversion
4.2
Configuring Settings for the Fibre Channel Ports
(CA Parameters)
Please be aware that only a homogeneous sharing with other BS2000 Servers is supported for FC Ports which
are connected to a BS2000 server. The combine Port Mode CA/RA is not supported by ETERNUS DX S2, but
tolerated as of ETERNUS DX S4/S3 and ETERNUS AF.
Note: In these terms the Management Unit (MU) and the Server Unit (SU x86) of an SE Server, resp. the
Server Unit of an SQ-Server are considered to be a BS2000 server, irrespective of whether Linux/Windows
guests are running or not on the Server Unit. The Application Unit of an SE Server /SQ-Server is a non-BS2000
server.
When setting a Fabric connection, complete the preparation work and set up the Fibre Channel switch
beforehand.
For further details, refer to "ETERNUS DX/AF Storage Systems Server Connection Guide (Fibre Channel) Fibre
Channel Switch Settings Administrator's Guide".
Controller
DX/AF series
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection-
Parameter
Connectivity > Port Group > FC
15
Copyright 2018 FUJITSU LIMITED
BS2000
Enable (Default)
No Conversion (Default)
Category
Action
Configure FC Port
P3AM-5672-10ENZ0