Features
The LEDs have the following meaning:
LED
A - CSS
(Customer Self
Service)
B - GEL
(Global Error
LED)
C - Identification blue on
D - Memory
E - CPU
F - System fan
G - PCI card
H - iRMC
30
Indicator
Meaning
off
no error (CSS component)
yellow on
indicates a prefailure (CSS component)
yellow flashing indicates a failure (CSS component)
off
no error (non CSS component)
orange on
indicates a prefailure (non CSS
component)
orange flashing indicates a failure of a non CSS
component.
Reasons for a failure may be:
– over temperature measured by one of
– sensor is defective
– CPU error
– software detected an error
server is identified via the ServerView
Operations Manager or by ID button
blue flashing
local monitor off
off
memory module running
orange on
memory module failure
off
CPU okay
orange on
CPU failure
off
fan running
orange on
fan failure
off
PCI card okay
orange on
PCI card failure (PCI card installed on riser
card)
off
iRMC S3 inactive
green flashing
iRMC S3 okay
Technical Manual
the sensors