5.4. DOCTOR:

The main board is installed on the back part, on the
right. The interface, protected by a cover, allows the
connection of the hardware key to the machine:
* Connect the handheld to the hardware key;
* Follows the instruction in the "WM DOCTOR"
manual.

5.5. TROUBLE SHOOTING:

PROBLEM
It does not switch on
It does not fill itself with
water
It continuously fills it-
self with water
The motor does not run
The drum does not rotate
It does not drain
Service Manual
Aqualtis - 2005
- Check the socket.
- Verify if the door closes the safety switch.
- Door micro door-lock
- Display board
- Tap closed or low pressure
- Solenoid valve clogged
- Solenoid valve not supplied
- Solenoid valve broken
- Drain tube too low
- Check pressure switch
- Air trap or pressure switch tube
- Check pressure switch
- Check motor winding
- Motor terminal box or board
- The motor is not under tension
- Check driving belt
- Check the motor
- Function excluded
- Check drain pump and filter
- Check drain pump tension
- Verify if the program provides drain block
- Check wall-drain