Indesit HOTPOINT LUCE DX1032CX Instrukcja serwisowa - Strona 30

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Piekarnik Indesit HOTPOINT LUCE DX1032CX. Indesit HOTPOINT LUCE DX1032CX 39 stron. Built-in touch control electronic multifunction 60 cm double oven

Indesit HOTPOINT LUCE DX1032CX Instrukcja serwisowa
Indesit
Company
SERVICING & DISMANTLING INSTRUCTIONS
SAFETY NOTES:
1) Disconnect the appliance from the electricity supply before commencing any work.
2) Beware of sharp edges on metal, plastic and glass parts.
3) Carry out insulation resistance, continuity and functional tests on the appliance after
service.
1)
To Access The Cooling Fan, Display Board & Main Power Board
1.
Remove the 4 screws on the oven front frame securing the oven to the housing.
2.
Using a suitable platform, e.g. Oven Standing Bench, Part Number 560154, remove the oven from
the housing.
3.
Remove the top cover 4 screws at the top and 2 at the rear.
2)
Cooling Fan
1.
Remove the top panel as in 1).
2.
Disconnect the wiring and remove the 3 screws securing the cooling fan to the duct.
3.
Reassemble in reverse order.
3)
Control Panel Glass
1.
Remove the top panel as in 1).
2.
Disconnect the wiring to the power board from the display board.
3.
Remove the 2 nuts, 10 mm securing the control panel glass.
4.
Grasping both sides of the control panel, lift slightly while gently pulling the top of the panel
forwards. Lift the panel to disengage from the 2 clips.
5.
Carefully disconnect the 2 ribbon cables to the display board.
6.
Disconnect the display board from the control panel by disengaging from the lower tabs first and
then lifting out from the support.
7.
Reassemble in reverse order making sure that both ribbon cables are firmly pushed back in place.
4)
Control Mounting Panel
1.
Remove the top panel as in 1).
2.
The control mounting panel is secured by 4 screws (2 left and 2 right).
3.
Reassemble in reverse order.
5)
Display Board
1.
Remove the top panel as in 1).
2.
Disconnect the wiring to the power board from the display board.
3.
Remove the 2 nuts, 10 mm securing the control panel glass.
4.
Grasping both sides of the control panel. lift slightly while gently pulling the top of the panel
forwards. Lift the panel to disengage from the 2 clips.
5.
Carefully disconnect the 2 ribbon cables to the display board.
6.
Disconnect the display board from the control panel by disengaging from the lower tabs first and
then lifting out from the support.
7.
Reassemble in reverse order making sure that both ribbon cables are firmly pushed back in place.
Service Manual UK
30 of 39
English