Indesit K 642 VS/G Instrukcja instalacji i użytkowania - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja instalacji i użytkowania dla Kuchenki Indesit K 642 VS/G. Indesit K 642 VS/G 16 stron. Indesit cooker with electric ventilated oven instructions for installation and use

Indesit K 642 VS/G Instrukcja instalacji i użytkowania
HOT PARTS
Important: make sure the supply pressure conforms with the
values shown in the table entitled "Caracteristics of the burners
and nozzles". When the cooker is installed between cabinets
(recessed), the gas connection must be effected by an
approved flexible hose with bayonet fitting
(BS 669 Current Edition). The gas inlet for the cookers is a
threaded G 1/2 gas female fitting.
Connecting the gas supply
To make the connection, a flexible hose should be used
corresponding to the current gas regulations which are:
the hose must never be at any point in its lenght in contact
with the "hot" parts of the cooker;
the hose must never be longer than 1,5 metre;
the hose must not be subject to any tension or torsional
stress and it must not have any excessively narrow curves
or bottlenecks;
the hose must be easy to inspect along its entire length to
check its condition;
the hose must always be in good condition, never attempt
to repair.
Important: the installation must comply with gas safety
(installation and use) regulations 1984. In all cases for the above,
by low, a qualified, corgi approved engineer must be called for
installation.
Electrial connection
Power supply voltage and frequency: 230-240V a.c. 50 Hz.
Note: the supply cable must be positioned so that it never
reaches at any point a temperature 50°C higher than the room
temperature. The cable must be routed away from the rear vents.
Should you require it, you may use a longer cable, however,
you must ensure that the cable supplied with the appliance is
replaced by one of the same specifications in accordance with
current standards and legislation.
Your appliance is supplied with a 13 amp fused plug that can be
plugged into a 13 amp socket for immediate use. Before using
the appliance please read the instructions below.
WARNING - THIS APPLIANCE MUST BE EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE CARRIED
OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA approved fuse to
BS 1362 should always be used, and the fuse cover re-fitted. If
the fuse cover is lost, the plug must not be used until a
replacement is obtained.
Replacement fuse covers:
If a replacement fuse cover is fitted, it must be of the correct
colour as indicated by the coloured marking or the colour that is
embossed in words on the base of the plug. Replacements can
be obtained directly from your nearest Service Depot.
Removing the plug:
If your appliance has a non-rewireable moulded plug and you
should wish to remove it to add a cable extension or to re-route
the mains cable through partitions, units etc., please ensure
that either:
the plug is replaced by a fused 13 amp re-wireable plug
bearing the BSI mark of approval.
or:
the mains cable is wired directly into a 13 amp cable outlet,
controlled by a switch, (in compliance with BS 5733) which
is accessible without moving the appliance.
Please note: for appliances with a rating greater than 13 amp
(eg: electric hob, double ovens and freestanding electric cookers
etc.) the mains cable must be wired into a cooker output point
with a rating of 45 amp. In this case the cable is not supplied.
Disposing of the plug:
Ensure that before disposing of the plug itself, you make the
pins unusable so that it cannot be accidentally inserted into a
socket. Instructions for connecting cable to an alternative plug:
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
If the colours of the wires in the mains lead do not correspond
with the coloured markings identifying the terminals in your plug,
proceed as follows:
Connect Green & Yellow wire to terminal marked "E" or
coloured Green or Green & Yellow.
Connect Brown wire to terminal marked "L" or coloured Red.
Connect Blue wire to terminal marked "N" or coloured Black.
If a 13 amp plug (BS 1363) is used it must be fitted with a 13
amp fuse. A 15 amp plug must be protected by a 15 amp fuse,
either in the plug or adaptor or at the distribution board. If you
are in any doubt about the electrical supply to your machine,
consult a qualified electrician before use.
How to connect an alternative plug:
The wires in this mains lead are coloured in accordance with
the following code:
BLUE
BROWN
GREEN AND YELLOW
GREEN &
YELLOW
13 amp fuse
BROWN
CROSS-BAR
BLUE
CORD GRIP
Disposing of the appliance
When disposing of the appliance please remove the plug by
cutting the mains cable as close as possible to the plug body
and dispose of it as described above.
Adapting the cooker to different types of gas
In order to adapt the cooker to a different type of gas with
respect to the gas for which it was produced (indicated on
5
- Earth
- Neutral
- Live
"NEUTRAL" ("N")
"LIVE" ("L")
"EARTH" ("E")
or