Indesit K3E51/EU Instalacja i instrukcja obsługi - Strona 4
Przeglądaj online lub pobierz pdf Instalacja i instrukcja obsługi dla Kuchenki Indesit K3E51/EU. Indesit K3E51/EU 23 stron.
The following instructions should be read by a qualified
technician to ensure that the appliance is installed, regulated
and technically serviced correctly in compliance with current
regulations.
Important: disconnect the cooker from the electricity when
making any adjustement, maintenance operation, etc.
Positioning
The appliance can be installed next to furniture units which
are no taller than the top of the cooker hob. For proper
installation of the cooker, the following precautions must be
taken:
a) Kitchen cabinets installed next to the cooker that are taller
than the top of the hob must be situated at least 200 mm
from the edge of the hob.
b) Hoods must be installed according to the requirements
in the installation manual for the hoods themselves and
in any case at a minimum distance of 650 mm.
c) Place the wall cabinets adjacent to the hood at a minimum
height of 420 mm from the hob (see figure).
d) Should the cooker be installed beneath a wall cabinet,
the latter should be situated at least 700 mm (millimetres)
away from the hob, as shown in the figure.
e) the cut-out for the cooker cabinet should have the
dimensions indicated in the figure.
Min.
Levelling your appliance (only on a few models)
Your cooker is supplied with feet for levelling the appliance. If
necessary, these feet can be screwed into the housings in
the corners of the cooker base (Fig. A).
Mounting the legs (only on a few models)
Press-fit legs are supplied which fit under the base of your
cooker (Fig. B).
Fig. A
Electrical connection
The power supply cable since its size depends on the electric
connection (see the following connection diagram).
Installation
HOOD
600
mm.
Fig. B
400 3N
H05RR-F 5x2.5 CEI-UNEL 35363
400V 2N
H05RR-F 4x2.5 CEI-UNEL 35363
230V 1N
H07RN-F 3x4 CEI-UNEL 35364
Feeding cable installation
Terminal block opening:
· Unscrew screw "V" (Fig. C)
· Pull and open the junction block lid
For the installation of the feeding cable carry out the following
operations:
· position the small connection A-B according to the type
of connection that has to be performed using the scheme
shown in the figure D.
Note: the small connections are prepared by the Factory for
the 230V monophase connection (contacts 1-2-3 are
connected to one another). The bridge 4-5 is situated in the
lower part of the terminal block.
· introduce the cables (N and
and tighten the relative screws.
· fix the remaining cables on the 1-2-3 clips.
· fix the feeding cable in the special cable stop and close
the cover fastening it with the screw "V".
V
Fig. C
Connecting the supply cable to the mains
Fit a plug, normalised for the load indicated on the data plate,
on the cable; when making the connection directly to the
mains, an omnipoIar switch with a minimum opening of 3
mm between the contacts, must be installed between the
appliance and the mains. This switch must be sufficient for
the load and must comply to regulations in force (the earthing
wire must not be interrupted by the switch). The power supply
cable must be positioned so that it does not exceed 50°C
more than room temperature at any point of its length. Before
making the connection check that:
· the limiter valve and the home system can support the
appliance load (see data plate);
· the power supply system has an efficient earthing
connection which complies with the provisions of current
regulations;
· the socket or omnipoar circuit-breaker is easily accessible
once the cooker has been installed. The plug and socket
must be easily accessible.
4
1
2
3
4
5
T
N
S
R
1
2
3
4
5
R
S N
4
1
2
3
5
N
R
$
) as shown in the figure
3
2
1
B
A
N
Fig. D