AEG 570 D Instrukcja obsługi i instalacji - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja obsługi i instalacji dla Okap wentylacyjny AEG 570 D. AEG 570 D 19 stron. Electrolux group. cooker hood operating and installation instructions dl 4150, chdl 4150, dl 6250, 570 d, 5708 d
Również dla AEG 570 D: Instrukcja obsługi i instalacji (20 strony), Instrukcja obsługi i instalacji (20 strony), Instrukcja obsługi i instalacji (20 strony), Instrukcja obsługi i instalacji (20 strony)

AEG 570 D Instrukcja obsługi i instalacji

Safety warnings

For the user

• The cooker hood is designed to extract unpleasant odours from the
kitchen, it will not extract steam.
• Always cover lighted elements, to prevent excess heat from
damaging the appliance. In the case of oil, gas and coal fired
cookers it is essential to avoid open flames.
• Also, when frying, keep the deep frying pan on the cooker top/
cooker under careful control.
• The hot oil in the frying pan might ignite due to overheating.
• The risk of self-ignition increases when the oil being used is dirty.
• It is extremely important to note that overheating can cause a fire.
• Never carry out any flambé cooking under the hood.
• Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch
off the automatic circuit breaker).
• It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, resulting in a fire hazard.

For the installer

• When used as an extractor unit, the hood must be fitted with a
120mm diameter hose.
• When installing the hood, make sure you respect the following
minimum distance from the top edge of the cooking hob/ring
surfaces:
electric cookers
gas cookers
coal and oil cookers
• The national standard on fuel-burning systems specifies a maxi-
mum depression of 0.04 bar in such rooms.
• The air outlet must not be connected to chimney flues or combus-
tion gas ducts. The air outlet must under no circumstances be
connected to ventilation ducts for rooms in which fuel-burning
appliances are installed.
• The air outlet installation must comply with the regulations laid down
by the relevant authorities.
• When the unit is used in its extractor version, a sufficiently large
ventilation hole must be provided, with dimensions that are
650 mm
750 mm
800 mm min.
3