MAKE ELECTRICAL CONNECTIONS

WARNING: Risk of electric shock.
the power before performing the following
procedures.
WARNING: Risk of electric shock.
bathtub to properly grounded, grounding-type
power line protected by Residual Current Device
(RCD).
NOTICE:
1. A qualified electrician must install one RCD-
protected, 220 V, 30 A, grounded outlets for the
system. No other load should be on these circuits.
2. Equipotential position is near water pump bracket to
connect to the construction ground.
For corner installation or peninsular installation:
·
Select the corresponding side panel. If the side
panel on the side of the faucet is selected, the side
frame K-23771T (the options) should also be
selected.
·
Carefully install the gap panel in place, align the
side frame with the inner edge of the gap panel,
mark the position of the fixing holes on the wall,
remove the side frame, drill holes in the wall and
install the anchor, then install the side frame again
and tighten the screws. Apply the silicone sealant
into the gap between side frame and front apron.
1397340-T01-A
Disconnect
Connect
Heated Back
Heater
100%
Silicone Sealant
-10-
(RCD)
Power Input
220-240V
Air Pump
Water Pump
1.
220 V 30 A
2.
·
K-23771T(
·
Screw
Frame Side
RCD
)