Kohler C3-050 Skrócona instrukcja obsługi - Strona 2

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Armatura łazienkowa Kohler C3-050. Kohler C3-050 2 stron. Elongated bidet toilet seat
Również dla Kohler C3-050: Skrócona instrukcja obsługi (2 strony), Instrukcja instalacji (25 strony), Podręcznik właściciela domu (35 strony), Instrukcja instalacji (13 strony), Skrócona instrukcja obsługi (2 strony), Podręcznik (2 strony)

Kohler C3-050 Skrócona instrukcja obsługi
13-1/4"
(337 mm)
Min
18-5/8"
(473 mm) -
19-3/8"
(492 mm)
15-9/16" (395 mm)
16-15/16" (430 mm)
Required Electrical Service
One dedicated circuit required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI). Outside North America,
this device may be known as a Residual Current Device (RCD).
Bidet toilet seat:
120 V, 15 A, 60 Hz
Technical Information
All product dimensions are nominal.
Seat shape type:
Elongated
Seat front type:
Closed-front
Seat-mounting holes:
5-1/2" (140 mm)
Electrical component
Bidet toilet seat: 120 V, 15 A, 60 Hz, 1800
rating:
W
Power cord length:
43" (1092 mm)
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
10-18-2019 05:38 - US/CA
5-1/2"
(140 mm)
1-1/4"
(32 mm)
Min
8-5/16"
(210 mm)
11-7/16"
(291 mm)
elongated cleansing toilet seat
4-3/4"
(121 mm)
20-11/16"
(525 mm)
16-3/16"
(411 mm)
1-7/16"
(36 mm)
Notes
Install this product according to the installation
guide.
Connect the seat to a cold water supply of
drinking quality water at a pressure of 20 psi - 80
psi (139 kPa - 551 kPa).
Do not install this seat in a location where: (1)
water might be splashed on the product or (2)
excessive moisture, high humidity levels, or
condensation is present. This will avoid damage
to the electronic components.
Do not use an extension cord with this product.
To avoid possible product malfunction, do not
plug in the seat until instructed to do so.
Locate the recepticle at least 6" (152 mm) above
the floor, and within a 32" (813 mm) radius
measured 2" (51 mm) from the bowl ledge.
C³ -050
K-18751
32" (813 mm) R.
2"
(51 mm)
6" (152 mm) Min
Electrical Service Detail