Install a GFCI-protected 120 V, 15 A grounded outlet. Install a second
GFCI-protected outlet for "H" models for the heater.
Optional Heater (models may vary)
either T-style (shown) or water intake
(not shown).
Make sure air actuator tubing is securely
attached to the pump or the optional timer box.
NOTE: Pump model illustrated may differ from your actual product.
9. Make Electrical Connections
WARNING: Risk of electric shock. Make sure the power has been disconnected before performing the
following procedures.
WARNING: Risk of electric shock. To reduce the risk of electrical shock, connect the pump and in-line
heater (if heater option included) to properly grounded, grounding-type receptacles protected by
Ground-Fault Circuit-Interrupters (GFCI's). Do not remove the plugs' grounding pins. Do not use
grounding adapters.
Pump Wiring
NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also
identifies the electrical rating of the whirlpool.
Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control
has been completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A,
grounded outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool,
and within 24" (61 cm) of the pump.
Plug the pump into this outlet.
NOTE: Make sure the air actuator tubing is securely attached to the pump, and is not kinked or damaged.
If a K-1639 Timer Kit will be used, install it now according to the instructions packed.
In-line Heater Wiring
"H" Models: The heater is equipped with a cord and plug. All wiring of the heater has been
completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded
outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool, and within
24" (61 cm) of the heater.
Plug the heater into this outlet.
Kohler Co.
Bond in accordance with applicable codes.
11
Plug pump and heater into
these outlets.
1055820-2-A