Kohler K-1154-HC Instrukcja uruchomienia - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja uruchomienia dla Wanny Kohler K-1154-HC. Kohler K-1154-HC 4 stron. Bath whirlpool
Również dla Kohler K-1154-HC: Instrukcja instalacji (48 strony)

Kohler K-1154-HC Instrukcja uruchomienia
56-1/2"
(143.5 cm) 30-3/4" (78.1 cm)
30-3/4"
(78.1 cm)
54"
(137.2 cm)
Product Information
Applicable product:
Drop-in rim style with heater, custom pump
location
Fixture*:
Bathing well:
Basin area, bottom
44" (111.8 cm) x 36" (91.4 cm)
Basin area, top
56" (142.2 cm) x 43" (109.2 cm)
Weight
70 lbs (31.8 kg)
To overflow:
Water depth
15" (38.1 cm)
Capacity
76 gal (287.7 L)
* Approximate measurements for comparison only.
Pump:
V
Pump: 1-speed
120
Heater: 1.5 kW
120
Minimum access panel
pump/control (required):
1012948-1-C
4-7/8"
(12.4 cm)
13"
(33 cm)
26" (66 cm)
54" (137.2 cm)
1-1/2" OD
K-1154-HC
Hz
A
60
7.5
60
12.5
20" (50.8 cm) W x
15" (38.1 cm) H
26" (66 cm)
39-3/4" (101 cm)
Pump/Control Access
20" (50.8 cm) W x 15" (38.1 cm) H
2-5/8" (6.7 cm)
2-7/8" (7.3 cm)
3" (7.6 cm)
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump and heater.
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
36 lbs/square foot (176 kg/square meter) loading.
Pump must be relocated to custom position at the time of
installation. Provide adequate clearance.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
2
No change in measurements if connected with
drain illustrated. (K-11677 or K-11677M)
Drop-in Rim Detail
52-1/2"
(133.4 cm)
1/2" (1.3 cm)
1-1/2"
(3.8 cm)
135˚
135˚
25" (63.5 cm)
Cut-out Detail
20-1/2"
(52.1 cm)
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
Kohler Co.